5. Function Settings
Functions Address
Data
Gain 001
0:
0
dB
1: + 6 dB
2: + 12 dB
3: Manual
Gain
(Refer to Address 008)
E-Shutter 002
0:
1/30s(OFF)
7:
1/2000s
1: 1/60s
8: 1/4000s
2: 1/100s
9: 1/10000s
3: 1/120s
4: 1/250s
5: 1/500s
10
~
15: 1/30s(OFF)
6: 1/1000s
16: Manual
Shutter
(Refer to Address 009&010)
White Balance
003
0: 2600K
1: 3200K
2: 5600K
3: 9000K
4: Manual White Balance
Trigger Mode
004
0: Trigger Mode OFF
1: Fixed Shutter Trigger Mode
(Shutter speed can be set with address 002.)
2: Pulse Width Trigger Mode
(Shutter speed can be set with trigger pulse width.)
Trigger Polarity
005
0: Positive Input
1: Negative
Input
No Function
006
0: Do not change
SYNC ON/OFF
007
0: SYNC
OFF
1: G SYNC ON
2: RGB ON SYNC
Manual Gain Control 008
0
~
255: 0dB
~
+12dB
※
Set the data of address 001 to 004.
Manual Shutter Control
009&010
0
~
524: 1/30
~
1/10000s
※
Set the data of address 002 to 016.
Address 009 MSB and address 010 LSB makes 10bit in total.
Shutter Speed
=
(791.5-Data)×42.33
μ
s
Max Data = 317Ch = 791
Manual White Balance
R-Gain Control
011
0
~
255
Covers variable range 2600
~
9000K.
Manual White Balance
B-Gain Control
012
0
~
255
Covers variable range 2600
~
9000K.