background image

VCC-F40X34  

Rev.900-676-32-00

 

©2010 CIS Corporation. All rights reserved. 

 

5

4.  Specification 

4.1.  General Specification 

Item Specification 

Pickup device 

Device Type 

1/3 type Interline Transfer color CCD, Sony ICX204AK 

Effective Pixel Number 1034(H) x 779 (V) 
Unit Cell Size 

4.65

μ

m (H) x 4.65

μ

m (V) 

Chip Size 

5.80mm (H) x 4.92mm (V) 

Video output frequency 

Pixel Clock 

30.0000 MHz 

Horizontal Frequency  23.622 kHz 

Pixel Clock 

1270 CLK 

Vertical Frequency 

1/30s Full Frame Scan Mode 
 

Scanning lines  792 H 

29.825 Hz 

Sync. system 

Internal sync & HD/VD external sync     

Video output standard  Analog RGB 
Resolution 

520 TV lines 

Sensitivity 

F 5.6    2000 lx (Shutter 1/30s, Gain 0dB, 3200K) 

Minimum illumination  F1.4    25 lx (Shutter 1/30s, max Gain VS 50IRE) 
Dust or stains in   
optical system 

No dust or stain shall be detected on the testing screen with setting the camera 
aperture at F16.     

Power requirements 

DC +12V 

±

  10% (Max voltage not to exceed 15V) 

Power consumption 

2.8 W (at DC +12V IN) 

Dimension 

Refer to overall dimension drawing (Clause 11) 

44mm x 44mm x 77mm (excluding projection) 

Mass 

Approx. 170 g 

Lens mount 

C mount (Refer to overall dimension drawing) 

Optical axis accuracy  Refer to drawing for CCD Optical Axis Accuracy (Clause 10) 
Gain variable range 

0

12dB (guaranteed range) 

Trigger Mode 

Fixed Shutter Trigger Operation 

Pulse Width Trigger Operation 

Shutter speed   
variable range 

1/30 (OFF), 1/60, 1/100, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 
1/10000s 
Shutter speed set by trigger pulse width: 1/4

1/10000s (per 1H) 

Summary of Contents for VISION analog VCC-F40X34

Page 1: ...VCC F40X34 Rev 900 676 32 00 2010 CIS Corporation All rights reserved XGA Color Analog Camera VCC F40X34 Product Specification Operational Manual CIS Corporation English...

Page 2: ...sentative value 8 5 Function Settings 9 6 External Connector Pin Assignment 11 7 Timing Chart 12 7 1 Horizontal Synchronous Timing Chart 12 7 2 Vertical Synchronous Timing Chart 12 7 3 Fixed Trigger S...

Page 3: ...operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable fli...

Page 4: ...duct Outline VCC F40X34 is a high resolution industrial color analog camera module utilizing a 1 3 type PS IT CCD 800K pixels CCD image sensor with on chip micro lenses realizes high sensitivity and h...

Page 5: ...0s Gain 0dB 3200K Minimum illumination F1 4 25 lx Shutter 1 30s max Gain VS 50IRE Dust or stains in optical system No dust or stain shall be detected on the testing screen with setting the camera aper...

Page 6: ...5 Immunity FCC To be applied Durability Vibration Acceleration 98 m s2 10 0G Frequency 20 200 Hz Direction XYZ 3 directions Testing time 120 min for each direction Shock No malfunction shall be occurr...

Page 7: ...ly switched by HD recognition Allowable frequency deviation 1 HD VD WEN SYNC output 2 5 0V Negative polarity output Trigger input Polarity Trigger Positive Negative selectable with address 005 Trigger...

Page 8: ...VCC F40X34 Rev 900 676 32 00 2010 CIS Corporation All rights reserved 8 4 3 CCD Spectral Response Representative value Lens characteristics and illuminant characteristics are not considered...

Page 9: ...e Shutter speed can be set with address 002 2 Pulse Width Trigger Mode Shutter speed can be set with trigger pulse width Trigger Polarity 005 0 Positive Input 1 Negative Input No Function 006 0 Do not...

Page 10: ...y mistake please turn off the power once Data Save 063 Input 083 to save address 000 014 into EEP ROM Fixed Shutter Trigger Mode Fixed Shutter Trigger Mode is a trigger operation to set shutter value...

Page 11: ...lar Connector HR10 10R 12PA HIROSE 9 pins D SUB Connector 6 pins Circular Connector HR 10 7R 6PA Pin No 1 GND 2 Power In DC 12V 3 GND 4 NA 5 GND 6 HD In Out 7 VD In Out 8 GND 9 NA 10 WEN Out 11 Trig I...

Page 12: ...Signal Output G Signal G ON SYNC Mode 1024CLK Active Area 792 1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26 791 790 789 788 27 HD Signal Output VD Signal Output WEN Signal Output Video Signal Output G Signal...

Page 13: ...ime ADDRESS 002 Input Trigger Signal Expousure Time VD Signal WEN Signal Video Signal Expousure Time Pulse Width Expousure Time Pulse Width Input Trigger Signal Expousure Time VD Signal WEN Signal Vid...

Page 14: ...Camera mode Camera No shall consist of 6 bytes of characters numeric strings Send the individual camera number code or common number code 000000 The reply data from the camera shall contain the regis...

Page 15: ...g modes consecutively 10ms after receiving reply from the camera should be waited to send the next command 9 Initial Settings Function Address Data Gain 001 0 0dB E Shutter 002 0 1 30s OFF White Balan...

Page 16: ...xis to datum plane 8 77 The center of effective pixels shall be within f 0 6 to the center of the lens mount Inclination of effective pixels to datum plane shall be 0 5 Dimension from datum plane to t...

Page 17: ...OUT IN OFF ON HD VD 75O DC IN REMOTE RGB SYNC Product Name Label 69 26 0 1 4 C Mount screws comply with ANSI ASME B1 1 1 32UN 2B Screw length from C mount lens surface shall be under 6mm And protrudin...

Page 18: ...peration manual In case damage or losses are caused by use contrary to the instructions in this product specification operation manual In case damage or losses are caused by malfunction or other probl...

Reviews: