VCC-F40X34
Rev.900-676-32-00
©2010 CIS Corporation. All rights reserved.
15
Remote controller address
Note: Do not write the data into the address other than specified, since it may cause the
damages or malfunction of the camera.
Remote controller data
Set the decimal number (000
~
255) for the remote controller data. Please be noted to set any
dummy data at read control mode.
CR
Be sure to input “CR” to confirm the end of the command.
※
When changing modes consecutively, 10ms after receiving reply from the camera should be waited to
send the next command.
9. Initial Settings
Function Address
Data
Gain 001
0:
0dB
E-Shutter 002
0:
1/30s(OFF)
White Balance
003
1: 3200K
Trigger Mode
004
0: Trigger Mode OFF
Trigger Polarity
005
1: Negative Input
SYNC ON/OFF
007
0: SYNC OFF
Manual Gain Control
008
Not specified
Manual Shutter Control
009&010 Not specified
Manual White Balance
R-Gain Control
011 Not
specified
Manual White Balance
B-Gain Control
012 Not
specified
Trigger Reset Mode
014
0: H-Synchronous Mode
75
Ω
Terminal
Rear Panel SW(UP):75
Ω
Terminal ON
HD/VD IN or OUT
Rear Panel SW(UP):HD/VD IN