8. Remote Interface Function   

Through RS-232C interface, the camera can be controlled by external PC. 

(1)

 

The settings for RS-232C 

 
 
 
 
 

(2)

 

Control code 

・ 

The total control code is 14 bits, which conforms to ASCII code. 

・ 

The control code consists of camera No. process code, remote controller address, remote controller 
data, and CR.    Execute Read/Write through PC, and the camera will reply the data. 
 

1 2 3 4 5 6  7th 

Byte 

10 

11 12 13 14 

Camera No. 

Process code 

Remote controller 
address 

Remote 
controller data 

CR 

00000: Common to the all 
cameras. 
Individual camera No. 

“R” Read mode 

Please refer to the 
address table of   
5. Function settings 

000

255 

0 Dh 

“W” Write mode 
“C” Camera 
mode 

 

Camera No. shall consist of 6 bytes of characters/numeric strings. 
 

Send the individual camera number code or common number code, “000000”. 

 

The reply data from the camera shall contain the registered number for that camera. 

Process code 
 

Input any one of R, W, or C to the process code. 

 

R (read mode) is to read the data of remote controller address. 
 Please be noted to set any dummy data (000

255) to 11

th

 

13

th

, since a command shall consists 

of 14 bytes. 
W (write mode) is to write the data to the remote controller address. 
Please be noted that the data cannot be saved into EEPROM of the camera. 
(Reboot the camera, and the data is reset to the initial setting.) 
To save the data into EEPROM, please refer to Clause 5. Function Settings. 
 
C is the code to send the data back from the camera. 

Note: Do not set code C when sending the data from PC side. 

 

Baud rate 

:

 

9600bps 

Data :

 

8bit 

Stop bit 

:

 

1bit 

Parity :

 

None 

XOn/XOff :

 

Not controlled 

Summary of Contents for VISION analog VCC-F40X34

Page 1: ...VCC F40X34 Rev 900 676 32 00 2010 CIS Corporation All rights reserved XGA Color Analog Camera VCC F40X34 Product Specification Operational Manual CIS Corporation English...

Page 2: ...sentative value 8 5 Function Settings 9 6 External Connector Pin Assignment 11 7 Timing Chart 12 7 1 Horizontal Synchronous Timing Chart 12 7 2 Vertical Synchronous Timing Chart 12 7 3 Fixed Trigger S...

Page 3: ...operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable fli...

Page 4: ...duct Outline VCC F40X34 is a high resolution industrial color analog camera module utilizing a 1 3 type PS IT CCD 800K pixels CCD image sensor with on chip micro lenses realizes high sensitivity and h...

Page 5: ...0s Gain 0dB 3200K Minimum illumination F1 4 25 lx Shutter 1 30s max Gain VS 50IRE Dust or stains in optical system No dust or stain shall be detected on the testing screen with setting the camera aper...

Page 6: ...5 Immunity FCC To be applied Durability Vibration Acceleration 98 m s2 10 0G Frequency 20 200 Hz Direction XYZ 3 directions Testing time 120 min for each direction Shock No malfunction shall be occurr...

Page 7: ...ly switched by HD recognition Allowable frequency deviation 1 HD VD WEN SYNC output 2 5 0V Negative polarity output Trigger input Polarity Trigger Positive Negative selectable with address 005 Trigger...

Page 8: ...VCC F40X34 Rev 900 676 32 00 2010 CIS Corporation All rights reserved 8 4 3 CCD Spectral Response Representative value Lens characteristics and illuminant characteristics are not considered...

Page 9: ...e Shutter speed can be set with address 002 2 Pulse Width Trigger Mode Shutter speed can be set with trigger pulse width Trigger Polarity 005 0 Positive Input 1 Negative Input No Function 006 0 Do not...

Page 10: ...y mistake please turn off the power once Data Save 063 Input 083 to save address 000 014 into EEP ROM Fixed Shutter Trigger Mode Fixed Shutter Trigger Mode is a trigger operation to set shutter value...

Page 11: ...lar Connector HR10 10R 12PA HIROSE 9 pins D SUB Connector 6 pins Circular Connector HR 10 7R 6PA Pin No 1 GND 2 Power In DC 12V 3 GND 4 NA 5 GND 6 HD In Out 7 VD In Out 8 GND 9 NA 10 WEN Out 11 Trig I...

Page 12: ...Signal Output G Signal G ON SYNC Mode 1024CLK Active Area 792 1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26 791 790 789 788 27 HD Signal Output VD Signal Output WEN Signal Output Video Signal Output G Signal...

Page 13: ...ime ADDRESS 002 Input Trigger Signal Expousure Time VD Signal WEN Signal Video Signal Expousure Time Pulse Width Expousure Time Pulse Width Input Trigger Signal Expousure Time VD Signal WEN Signal Vid...

Page 14: ...Camera mode Camera No shall consist of 6 bytes of characters numeric strings Send the individual camera number code or common number code 000000 The reply data from the camera shall contain the regis...

Page 15: ...g modes consecutively 10ms after receiving reply from the camera should be waited to send the next command 9 Initial Settings Function Address Data Gain 001 0 0dB E Shutter 002 0 1 30s OFF White Balan...

Page 16: ...xis to datum plane 8 77 The center of effective pixels shall be within f 0 6 to the center of the lens mount Inclination of effective pixels to datum plane shall be 0 5 Dimension from datum plane to t...

Page 17: ...OUT IN OFF ON HD VD 75O DC IN REMOTE RGB SYNC Product Name Label 69 26 0 1 4 C Mount screws comply with ANSI ASME B1 1 1 32UN 2B Screw length from C mount lens surface shall be under 6mm And protrudin...

Page 18: ...peration manual In case damage or losses are caused by use contrary to the instructions in this product specification operation manual In case damage or losses are caused by malfunction or other probl...

Reviews: