VCC-SXCXP3R Rev. 905-0050-00
©2017 CIS Corporation. All rights reserved.
28
10. Factory Settings
DeviceControl
DeviceUserID
ID00DevU0000000H
DeviceIndicatorMode
Active
ImageFormatControl
SensorWidth
1280(=ROIOff)
SensorHeight
1024(=ROIOff)
SubsamplingMode
Subsampling_Off
PixelFormat
BayerRG8
TestImageMode
OFF
AquisitionControl
TriggerSelectorAndActivation
AcquisitionMode
TriggerSource
LinkTrigger0
ExposureTime
3333
AnalogControl
blackOffset
20
Gain
1
ShadingCorrection
FALSE
DefectivePixelCorrection
TRUE
BalanceWhiteControl
BalanceWhiteOnePushGainRed
1.0
BalanceWhiteOnePushGainBlue
1.0
DigitalIOControl
LineSource
SIGNAL_OFF
SequencerControl
SequencerActivation
Off
SequencerInformationLocation
Off
Index0
~
Index7
0
~
7
The same value as the
Index number
Index0Count
~
Index7Count
1
All 1
SequencerLoopCount
0
ActiveIndexNumber
0
ActiveIndexModeIndexNumber
0
SequencerExposureTime
1000.0
(Selector 0-7)
SequencerGain
1.0
(Selector 0-7)
TransportLayer
CxpLinkConfiguration
CXP_X1
※
Factory setting values are the same as the one for UserSetDefault command.