VCC-SXCL3R
Rev.
905-0046-00
©2016 CIS Corporation. All rights reserved.
14
Effective Line : 1024H
Effective Line
~ ~
Exposure Out
1
0
2
4
1
TRIG IN
FVAL
Video Out
LVAL
~ ~
1
0
2
4
1
Effective Line
Exposure Time
Delay
(A)
TRIG IN
Exposure Out
Exposure Time
Trigger input ignore period
Image
Header
IDLE
StreamPacket
Image
Header
StreamPacket
IDLE
IDLE
7.2.
Vertical Synchronous Timing
FVAL Out
1Frame = 1078H
Effective Line : 1024H
DVAL Out
~ ~
LVAL Out
~ ~
Effective Line
~ ~
~ ~
1024
1024
1
1
Video Out
Effective Line
ineffect
ive line
Effective Line
ineffect
ive line
V Blanking
5 or 54H
※
Ineffective lines occur when exposure start is overlapped at trigger mode as well.
7.3.
Fixed Trigger Shutter Mode
1Tap
:
13.72μS
delay
+
48nS jitter
2Tap
:
6.89μS
delay
+
24nS jitter
3Tap
:
3.51μS
delay
+
12nS jitter