VCC-GC21U11PCL
Rev.
900-763-30-00
z
The voltage ripple of camera power DC +12V
±
10% shall be within
±
50mV. Improper power
supply voltage may cause noises on the video signals.
z
The rising time of camera power supply voltage shall be less than +10V, Max 60ms. Please
avoid noises like chattering when rising.
10
40
20
30
50
10
11
12
[V]
Voltage Rising Time [ ms]
9
8
7
60
70
Pow
er
S
uppl
y
Volt
ag
e
z
Precautions to observe when using partial mode.
At vertical partial scan mode, the smaller the value of read-out lines setting is set, the faster the
camera exposure output speed goes, and the more the power consumption is required at the same
time.
Power requirement of when the minimum read-out line is set with partial scan will be approx 1.5
times more than the one with full frame scan. Naturally, heat of the camera will be increased.
Especially when the read-out line is set in the range of 100 lines to 1 line, heat dissipation is
recommended to install the camera.
Installation recommended.
・
Install the camera to the place with ambient temperature under 40
℃
.
・
Install the camera to a metallic component.
©2013 CIS Corporation. All rights reserved.
4