X is the code to respond when error is detected by the camera side. 

 

Details of the detected error can be checked with 4 lines of the 3

rd

 to 6

th

 byte.     

 

  0101: Abnormal address value 

 

  0102: Abnormal command 

 

  0103: Abnormal data value 

 

  0104: Abnormal data length (over 14byte) 

 

Remote controller address 

Note: Do not write the data into the address other than specified, since it may cause 
the damages or malfunction of the camera. 

 
Remote controller data 

Set the decimal number (000

255) for the remote controller data.    Please be noted to set any 

dummy data at read control mode. 

 
CR 
 

Be sure to input “CR” to confirm the end of the command. 

  Note: The data set with 2 Byte shall be set with High Byte (even address) first, then set with 

Low Byte (odd address).    The camera rewrites the internal resister when receiving Low Byte. 

   

(3)

 

Data Save 

 
Input data 083 or 053 into the address 127 to save the data to EEP-ROM. 
 

(4)

 

Initial Settings 

 
Input data 083 or 053 into the address 126 to return to the initial settings. 

 
 

 

10.

 

Initial Settings 

 

Function Address

Data 

Gain 001 

0: 

0dB 

Shutter 002 

0: 

1/140s(OFF) 

 

Trigger Shutter Mode 

004 

0: 

Normal Shutter Mode (Trigger OFF) 

Trigger Polarity 

011 

0:   

Positive 

Output Data Selection 

013 

0: 

8bit output 

Partial Scan Mode 

015 

0: 

Full Frame Scan Mode 

Output Image Flip Vertical 

021 

0: 

Normal 

Gain CC Control ON/OFF 

023 

0: 

OFF 

Baud Rate 

030 

0: 

9600bps 

Camera Mode 

031 

1:   

4Tap Medium Configuration Mode 

Summary of Contents for VCC-GC21U11PCL

Page 1: ...U11PCL Rev 900 763 30 00 English Camera link I F 2M Resolution CMOS B W Power over Camera Link VCC GC21U11PCL Product Specification Operational Manual CIS Corporation 2013 CIS Corporation All rights r...

Page 2: ...onfiguration mode 70fps 14 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 70fps 14 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 140fps Initial Setting...

Page 3: ...hot or cold places operating temperature 5 to 4 5 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subj...

Page 4: ...e smaller the value of read out lines setting is set the faster the camera exposure output speed goes and the more the power consumption is required at the same time Power requirement of when the mini...

Page 5: ...web 4 Specification 4 1 General Specification 1 Pickup Device Device Type Diagonal Length 12 775mm Global Shutter type B W CMOS Effective pixel number 2048 H x 1088 V Unit cell size 5 5 m H x 5 5 m V...

Page 6: ...e 19 Partial Scan Full Frame Scan 1 line 1 line step 20 Safety Quality standards UL Conform to UL Standard including materials and others CE EN55022 2010 Class A for Emission EN61000 6 2 2005 for Immu...

Page 7: ...5us Functionally no upper limitation is set but noises such as dark noises and shadings might be noticeable at long time exposure Trigger Input CC1 Camera Link input LVDS 5 Serial Communication SerTC...

Page 8: ...VCC GC21U11PCL Rev 900 763 30 00 4 3 CMOS Spectral Response Representative Value Lens characteristics and luminous source characteristics are not considered 2013 CIS Corporation All rights reserved 8...

Page 9: ...iguration Mode 38fps 2013 CIS Corporation All rights reserved 9 2 4Tap Medium Configuration Mode 75fps Initial Setting 3 8Tap Full Configuration Mode 150fps D D 1088 Line 2048pixel 1 2 D D D D 1088 Li...

Page 10: ...7500s 10 1 10000s 1 10000s 1 10000s 11 1 15000s 1 15000s 1 15000s 12 1 20000s 1 20000s 1 20000s 13 1 30000s 1 30000s 1 30000s 14 1 30000s 1 40000s 1 40000s 15 1 30000s 1 40000s 1 50000s 16 Manual Shu...

Page 11: ...hutter Speed 16 641us 1088 036 037 12 9us Min value 0 14 052ms 1 70s Max value 1087 29 541us 1 30000s 4Tap mode Shutter Speed 16 641us 1088 036 037 6 45us Min value 0 7 034ms 1 140s Max value 1087 23...

Page 12: ...e line numbers 5 088 089 1 1088 Set 0 when not in use Partial scan effective line numbers 6 090 091 1 1088 Set 0 when not in use Partial scan effective line numbers 7 092 093 1 1088 Set 0 when not in...

Page 13: ...21 SerTFG 8 Z0 21 Z0 9 CC1 Trigger IN 22 CC1 Trigger IN 9 Z1 22 Z1 10 CC2 23 CC2 10 Z2 23 Z2 11 CC3 24 CC3 11 Zclk 24 Zclk 12 CC4 25 CC4 12 Z3 25 Z3 13 GND 26 GND 12V PoCL 13 GND 26 NA 6 2 Power LED 1...

Page 14: ...cal Synchronous Signals Timing 2Tap Base Configuration Mode 70fps 2013 CIS Corporation All rights reserved 14 FVAL Out 1Frame 1104H 14 242ms Effective Line 1088H Effective Line DVAL Out LVAL Out Effec...

Page 15: ...ical Synchronous Signals Timing 4Tap Medium Configuration Mode 140fps 2013 CIS Corporation All rights reserved 15 FVAL Out 1Frame 1104H 7 121ms Effective Line 1088H Effective Line DVAL Out LVAL Out Ef...

Page 16: ...chronous Signals Timing 8Tap Full Configuration Mode 280fps 2013 CIS Corporation All rights reserved 16 FVAL Out 1Frame 1104H 3 560ms Effective Line DVAL Out Effective Line 1088H LVAL Out Effective Li...

Page 17: ...smission for the prior video output signals cannot be accepted If the next trigger is input prior to the completion of video transmission for the prior video output signals the image may be impacted T...

Page 18: ...rs can be accepted even when outputting video signals However trigger signals for exposure to start the next video output prior to the completion of video transmission for the prior video output signa...

Page 19: ...ine Number FVAL LVAL Video Out Partial scan start position 1 Address 064 065 Partial scan start position 3 Address 068 069 Partial scan effective lines 2 Address 082 083 Partial scan start position 2...

Page 20: ...line Camera Mode Time for 1 Line 2Tap Base Configuration Mode 12 9us 4Tap Medium Configuration Mode 6 45us 8Tap Full Configuration Mode 3 225us Setting Example Effective Lines Entire Frame Lines Frame...

Page 21: ...11 12 13 14 Camera No Process code Remote controller address Remote controller data CR 000000 fixed R Read mode Please refer to the address table of Section 5 Function Settings 000 255 0 Dh W Write m...

Page 22: ...ol mode CR Be sure to input CR to confirm the end of the command Note The data set with 2 Byte shall be set with High Byte even address first then set with Low Byte odd address The camera rewrites the...

Page 23: ...VCC GC21U11PCL Rev 900 763 30 00 11 CMOS Optical Axis Accuracy 2013 CIS Corporation All rights reserved 23...

Page 24: ...VCC GC21U11PCL Rev 900 763 30 00 12 Dimensions 2013 CIS Corporation All rights reserved 24...

Page 25: ...this product specification operation manual z In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified z In case damage o...

Reviews: