VCC-GC21U11PCL
Rev.
900-763-30-00
©2013 CIS Corporation. All rights reserved.
11
Function Address
Data
Table Selection for Gain CC
Control
024
0
~
7:
CC2 CC3 CC4
0: L L
L
1: H L
L
2: L H
L
3: H H
L
4: L L
H
5: H L
H
6: L H H
7: H H
H
Table Read/Write for Gain
CC Control
025 0: Nop
1: Table
Read
2: Table
Write
Manual Gain (Address 032&033) is written in to the table specified with
Address 024.
3: Clear
Table
Baud Rate
030
0:
9600bps
1: 19200bps
2: 38400bps
3: 57600bps
4: 115200bps
Camera Mode
031
0:
8Tap Full Configuration Mode (280fps)
1:
4Tap Medium Configuration Mode (140fps)
2:
2Tap Base Configuration Mode (70fps)
Manual Gain
032&033
0
~
767: 0:0dB
~
767:+12dB
Manual Shutter
036&037
0
~
1087:
2Tap mode: Shutter Speed
=
16.641us + (1088 - (036&037))
×
12.9us
Min. value 0: 14.052ms(1/70s), Max. value 1087: 29.541us(1/30000s)
4Tap mode: Shutter Speed
=
16.641us + (1088 - (036&037))
×
6.45us
Min. value 0: 7.034ms(1/140s), Max. value 1087:23.091us(1/40000s)
8Tap mode: Shutter Speed
=
16.641us + (1088- (036&037))
×
3.225us
Min. value 0: 3.525ms(1/280s), Max. value 1087: 19.866us (1/50000s)
※
Set the data of the address 002 to 016.
Cursor Indication ON/OFF 058
0:
OFF
1: ON
Cursor X Address
061&060
0
~
2047:
Cursor Y Address
063&062
0
~
1087:
Partial scan start position 1 064&065
0
~
1087:
Partial scan start position 2 066&067
0
~
1087:
Partial scan start position 3 068&069
0
~
1087:
Partial scan start position 4 070&071
0
~
1087:
Partial scan start position 5 072&073
0
~
1087:
Partial scan start position 6 074&075
0
~
1087:
Partial scan start position 7 076&077
0
~
1087:
Partial scan start position 8 078&079
0
~
1087:
※
Set the data of the address 015 to 001.