Shutter speed settings 
 

E2 

E1 

E0 

Shutter Speed 

Actual Time 

SW1  SW2  SW3   

Normal shutter mode 

Fixed trigger shutter mode 

OFF  OFF  OFF     

OFF (1/15s)   

66.7 ms 

33.5 ms 

OFF  OFF  ON 

1/120 sec 

9.74 ms 

9.84 ms 

OFF  ON 

OFF 

1/300 sec 

3.94 ms 

3.95 ms 

OFF  ON 

ON 

1/600 sec 

1.94 ms 

1.95 ms 

ON 

OFF  OFF 

1/1,250 sec 

952μs 

966μs 

ON 

OFF  ON 

1/2,500 sec 

455μs 

468μs 

ON 

ON 

OFF 

1/5,000 sec 

207μs 

220μs 

ON 

ON 

ON 

1/10,000 sec 

83μs 

95μs 

            Indicates initial setting position 

 

Shutter mode settings 
 

MODE1  MODE0  Setting Mode 
SW4 

SW5 

 

OFF     

 

 

     

 

OFF 

Normal shutter mode (including Restart-Reset mode) 

OFF 

ON 

Fixed trigger shutter mode (Sync Reset Mode) 

ON 

OFF 

Pulse width trigger shutter mode 1 (Sync Reset Mode) 

ON 

ON 

Pulse width trigger shutter mode 2 (Sync Non-Reset Mode) 

            Indicates initial setting position 
 

Table of settings 
 

 

Function 

Normal 

Shutter 

mode 

Fixed trigger 

shutter mode   

(Sync Reset) 

Pulse width trigger 

shutter mode 1 

(SYNC Reset) 

Pulse width trigger 

shutter mode 2 

(SYNC Non-Reset) 

Shutter settings by 
fixed switch 

 

× 

× 

Shutter settings by 
trigger pulse width 

× 

× 

 

 

Full Frame Scan mode 

 

 

 

 

Binning Scan mode 

 

 

 

 

Partial Scan mode 

 

 

 

 

HD/VD Input 

 

HD 

HD 

 

HD/VD Output 

 

 

 

× 

     

1 When using the camera at Restart-Reset mode, shutter speed settings shall be OFF. 

Summary of Contents for VCC-G20U20A

Page 1: ...VCC G20U20A Rev 900 618 35 00 2014 CIS Corporation All rights reserved 29mm Cubic UXGA Analog B W Camera VCC G20U20A Product Specification Operation Manual CIS Corporation English...

Page 2: ...1 Horizontal Synchronous Timing 14 7 2 Vertical Synchronous Timing 14 7 2 1 Full Frame Scan Mode 14 7 2 2 Binning Mode 15 7 2 3 1 2 Partial Scan Mode 15 7 2 4 1 4 Partial Scan Mode 16 7 3 Restart Res...

Page 3: ...operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable fli...

Page 4: ...inch PS IT CCD 2M pixels CCD image sensor with on chip micro lenses realizes high sensitivity and high resolution Only 29mm cubic in size excluding projection light weight 45g and speed makes it a bes...

Page 5: ...0 TV lines Sensitivity F8 400 lx Shutter 1 15s Gain 0dB 3200K Minimum illumination F1 4 1 0 lx Shutter 1 15s max Gain VS 50IRE S N ratio 52dB Dust or stains in optical system No dust or stain shall be...

Page 6: ...s 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Durability Vibration Acceleration 9...

Page 7: ...HD VD WEN output CMOS 74VHC04 equivalent Output impedance 100 HD VD WEN output signal level Low 0 5V max High 4V Min Trigger input Polarity Positive Input signal level Low 0 5V Max High 2 5 5V Input i...

Page 8: ...mode Pulse width trigger shutter mode 5 Mode0 6 Scan1 Scan mode 3bit Full frame scan mode Binning mode 1 2 1 4 partial scan mode 7 Scan0 8 Gain 0dB fixed Manual gain 9 Scan Enable Scan Enable No 9 pi...

Page 9: ...ings MODE1 MODE0 Setting Mode SW4 SW5 OFF OFF Normal shutter mode including Restart Reset mode OFF ON Fixed trigger shutter mode Sync Reset Mode ON OFF Pulse width trigger shutter mode 1 Sync Reset Mo...

Page 10: ...rigger shutter mode Sync Reset Mode With trigger input images at any timing can be captured with setting exposure time by the shutter value of switch at camera rear Internal SYNC and VD are reset righ...

Page 11: ...allen should be set between 150 s to 100ms Exposure time Trigger width s 4 7 s typical Conditions Trigger input pulse width shall be 4 s 250ms Positive Logic The shortest trigger cycle Trigger width V...

Page 12: ...ial scan mode 29 95 626 49 550 1 4 Partial scan mode 59 91 313 62 211 Changing the scan settings Scanning can be changed basically by the settings of camera switch at rear but it can be also changed b...

Page 13: ...rporation All rights reserved 13 6 External Connector Pin Assignment 12pins Circular Connector SNH 10 12 RPCB SAMWOO Pin No 1 GND 2 Power IN 12V 3 GND 4 Video Out 5 GND 6 HD In Out 7 VD In Out 8 GND 9...

Page 14: ...harge Signal Read Out Signal Black 48 45 135 s 150 4 2 s 30 6 s 1100 Transmit 204 Dummy Pixels 40 Effective Pixels 1628 1V 1252H 9H Video Output WEN Output 1228 1229 1236 1228 1229 1236 1 2 9 Effectiv...

Page 15: ...d 602 H 1235 6 Exposure Time 1V 626H 1217 8 1219 0 1235 6 1 2 1215 6 Effective Pixels Black 5 2 3 4 13 14 15 16 1213 4 WEN Output 626 9H High Speed Transmit Period 3H 43H 1V 626H 9 Video Output Active...

Page 16: ...smit Period Exposure Time Vertical Blankinng 62H 3H 56H Video Output Active Period 211H 40 9 V Pulse Read Out Signal Discharge Signal Video Output Camera VD At Full Frame Scan 1V min 1220H 32H Externa...

Page 17: ...Period 1V 1252H Trigger Input Read Out Signal Exposure Time Internal HD or External HD 1220 32 1 2 Video Output WEN Output Internal VD Output 1V 1252H At Full Frame Scan 1220 32 26 Trigger Input Read...

Page 18: ...Pulse Width External VD Input At Full Frame Scan 1220 32 26 Trigger Pulse Width 4 s 250ms 110 s min 55 s 70ms Video Active Period 1V 1252H Video Output Trigger Input Read Out Signal Exposure Time WEN...

Page 19: ...14 5 29 6 0 3 6 0 3 6 0 3 6 0 3 10 0 3 10 0 3 29 M2 M3 M2 Datum Plane The center of effective pixels shall be within 0 6 to the center of lens mount Inclination of effective pixels to datum plane sha...

Page 20: ...VCC G20U20A Rev 900 618 35 00 2014 CIS Corporation All rights reserved 20 9 Dimensions...

Page 21: ...re caused by use contrary to the instructions in this product specification operation manual In case damage or losses are caused by malfunction or other problems resulting from use of equipment or sof...

Reviews: