VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
25
・
Please choose from FrameStartRisingEdge/ FrameStartFallingEdge/ FrameStartLevelHigh/ FrameStartLevelLow
to set TriggerSelectorAndActivation in accordance with the way of control.
(1)Edge Control
The exposure time for each frame shall be controlled by sequence parameter set which is set beforehand.
(2)Pulse Width Control
Pulse width shall correspond to the exposure time for each frame. The exposure time for parameter set shall
not be referred.
※
Notes for command issuing timing for IndexSelectorModeIndexNumber
Please input the trigger pulse after confirmed ACK after issued IndexSelectorModeIndexNumber, to make sure
to reflect parameter set to the next frame.
9.6
Setting Items for Sequence Control
Please execute UserSetSave to save the settings. Please note that SequencerActivation shall not be saved, so it
shall be always OFF after turn ON the power. Please set it accordingly when use Sequence Mode.
◇
How to set Sequence control
Acquisition Control
TriggerSelectorAndActivation
AquisitionMode
FrameStartRisingEdge
FrameStartFallingEdge
FrameStartLevelHigh
FrameStartLevelLow
FrameBurstStart
・
FrameStartRisingEdge : To set sequence control to rising edge of trigger pulse
・
FrameStartFallingEdge : To set sequence control to falling edge of trigger pulse
・
FrameStartLevelHigh : To set sequence control to high level control of trigger pulse
・
FrameStartLevelLow : To set sequence control to low level control of trigger pulse
・
FrameBurstStart : To set sequence control at the use of burst mode.
◇
Shifting to sequence mode
SequencerControl
SequencerActivation
Off
FrameStartPredefined
FrameStartIndexSelector
FrameBurstStartEdge
FrameBurstStartLevel
FrameBurstStartSoftware
・
FrameStartPredefined
: To set to start trigger mode and burst mode
・
FrameStartIndexSelector : To set to start Index mode
Aegis Electronic Group, Inc.