background image

VCC-5CL4M

 

       

    

                                       

        

 

   

     

Rev.905-0060-04 

 

©2016 CIS Corporation. All rights reserved. 

29 

 

 

White Defects Detection by the users (Address 100). 

 
This is the function to register the pixels automatically if a pixel exceeds the level specified by the user.     
Please be noted that no lights should be in the sensor surface to use this function. 
 
There are 2 kinds of parameters for commands. 
 
The first parameter:     

Threshold (0~1023) 

   

 

 

 

The data with luminance level more than the specified level here shall be registered. 

 

 

 

 

※ 

In case of 8bit images, 4 times value of the image signal level shall be specified as the   

threshold value. 

   

 

 

 

 

The second parameter:    Additional Flag (0, 1) 

When 0 is specified, all of user’s white defects data registered by that time are cleared out,   
and data will be newly registered. 
When 1 is specified, only newly detected white defects data will be added to the old data   
registered by that time. 

 

 

Even when the Additional Flag 0 is specified, the added data with the Address 101 would not be deleted. 

 

 

Additional registration of defected pixels by users (Address 101). 
 
This is the function to register any defected pixels specifying its coordinate. 
There are 2 parameters as commands. 
 

The first parameter: X coordinate 
The second parameter: Y coordinate 

 

 

When the same defected pixel as the one registered at our Ex-factory was specified, it shall be ignored.   

 

 

Deletion of defected pixels data registered by users (Address 102). 

 

This is the function to delete the defected pixels data detected and registered by the users. 
There are 2 parameters as commands. 
 

The first parameter: X coordinate 
The second parameter: Y coordinate 

 

 

Only the registered data by users, with Address 100 or Address 101, can be deleted. 
The data registered at our ex-factory cannot be deleted by this command. 

 

 

Entire deletion of defected pixels data registered by users (Address 103). 

 

This is to delete all defected pixels data detected and registered by the users, with Address 100 and Address 101.   
Please execute this when you wish to redo your detection and registration from the beginning, or when you wish 
to restore all the registration to the factory settings.  SU 103 1 to execute. 

 
 

Summary of Contents for VCC-5CL4M

Page 1: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved Camera Link I F 5 01M Pixels CMOS B W Camera VCC 5CL4M Product Specifications Operational Manual CIS Corporation...

Page 2: ...Horizontal Synchronous Signals Timing 2Tap Base configuration mode 15 7 2 Vertical Synchronous Signals Timing 2Tap Base configuration mode 15 7 3 Horizontal Synchronous Signals Timing 3Tap Base confi...

Page 3: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 2 16 CMOS Pixel Defect 35 17 Product Support 35 18 Ordering Information 35...

Page 4: ...ht source sun etc and when camera is not in use put the lens cap on Follow the instructions in Chapter 6 External connector pin assignment for connecting the camera Improper connection may cause damag...

Page 5: ...Pulse width trigger shutter mode Full frame rate and video output are as below 3 System Configuration 3 1 Camera Camera VCC 5CL4M 3 2 Optional Accessories M42 C lens mount conversion ring M42 F lens m...

Page 6: ...8bit 10bit B W output 7 Sensitivity F4 400lx Shutter speed 1 58s OFF Gain 0dB 4tap8bit configuration mode 8 Minimum illumination F1 4 0 19lx Shutter speed 1 58s OFF Gain 36dB 4tap8bit configuration mo...

Page 7: ...Video output data Effective video output 2448 H 2048 V At full frame scan mode 2 Sync signal input and output LVAL No 6 pin 12pins circular connector LVTTL output FVAL No 7 pin EXPOSURE No 9 pin DVAL...

Page 8: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 7 4 3 CMOS Spectral Response The lens characteristics and illuminant characteristics are excluded...

Page 9: ...se configuration mode 28fps 2 3Tap Base configuration mode 42fps 3 4Tap Medium configuration mode 57 fps 4 8Tap Full 8tap10bit configuration mode 114fps D D 2048lines 2448pixels 1 2 D D D D 2048line 2...

Page 10: ...on cannot be operative at CLK sync mode This mode is effective to avoid hunting at high speed shutter operation 6 0 H sync mode Trigger is taken with H sync A trigger during outputting images can be i...

Page 11: ...e time with s approximate value Refer to the manual shutter settings of FAST trigger mode CLK sync mode Vertical partial lump settings 50 3 parameters The 1st parameter Partial number 0 7 The 2nd para...

Page 12: ...te the list of data at ex factory and the registered data by the user 2 at setup Indicate only the list of the registered data by the user 3 at setup Indicate the registered number of the defect pixel...

Page 13: ...ap Base configuration mode 16 633 s 3Tap Base configuration mode 11 111 s 4Tap Medium configuration mode 8 350 s 8Tap configuration mode 4 175 s The minimum setting value shall be 1 and the maximum se...

Page 14: ...ed 13 6 External Connector Pin Assignment 6 1 12pins Circular Connector HR10 10R 12PA 73 HIROSE or equivalent Pin No Description 1 GND 2 Power input DC 12V 3 GND 4 NC 5 GND 6 LVAL output 7 FVAL output...

Page 15: ...Please make sure that power is OFF when changing the switch settings If the switch setting was changed while power is ON it may cause malfunction or damages to the camera Pin No Description Pin No De...

Page 16: ...k Port B Camera Link Port A 1 3 5 7 2 4 6 8 2440 2442 2445 2447 2441 2443 2446 2448 1 2 Video Out 2 4 4 7 2 4 4 8 Camera Link CLK 74 25MHz 7 2 Vertical Synchronous Signals Timing 2Tap Base configurati...

Page 17: ...era Link Port A 1 3 4 6 2 5 2443 2445 2446 2448 2444 2447 1 2 Video Out 2 4 4 7 2 4 4 8 3 4 2 4 4 5 2 4 4 6 5 6 2 4 4 3 2 4 4 4 Camera Link CLK 74 25MHz 7 4 Vertical Synchronous Signals Timing 3Tap Ba...

Page 18: ...k Port B Camera Link Port A 1 3 5 7 2 4 6 8 2441 2443 2445 2447 2442 2444 2446 2448 1 2 Video Out 2 4 4 7 2 4 4 8 3 4 2 4 4 5 2 4 4 6 Camera Link CLK 74 25MHz 7 6 Vertical Synchronous Signals Timing 4...

Page 19: ...1 2 Video Out 2 4 4 7 2 4 4 8 3 4 2 4 4 5 2 4 4 6 Camera Link Port H Camera Link Port G Camera Link Port F Camera Link Port E 5 7 6 8 2445 2447 2446 2448 5 6 7 8 2 4 4 3 2 4 4 4 2 4 4 1 2 4 4 2 Camer...

Page 20: ...ode Time for 1 line 2Tap Base configuration mode 16 633 s 3Tap Base configuration mode 11 111 s 4Tap Medium configuration mode 8 350 s 8Tap configuration mode 4 175 s There is an exposure time period...

Page 21: ...5 s Input more than 1 s width pulse as a trigger There is an exposure time period for approx 13 73 s at the edge right after exposure output Trigger input while outputting images cannot be accepted Tr...

Page 22: ...exposure time would change so that flicker might be noticeable in the image especially when high speed shutter is set This flicker sometimes can be eliminated when fixed trigger shutter mode is used...

Page 23: ...pulse width of the trigger signals Trigger operation is CLK sync and V sync restart system The delay time Exposure Time Delay from detecting trigger edge in the camera to starting exposure is approx...

Page 24: ...Effective Line Exposure Out 2 0 4 8 1 TRIG IN LVAL Out FVAL Out Video Out DVAL Out Effective Line Trigger input ignore period Exposure Time Exposure Time Delay Exposure Time Delay A TRIG IN Exposure...

Page 25: ...n Effective Lines 3 Partial Scan Effective Lines 1 Partial Scan Setting Sequence of Video Output Partial area 1 Partial area 2 Partial area 3 When setting several partial scan areas please set the sta...

Page 26: ...1070 84 1 1070 111 9 1070 223 8 1070 Vertical UXGA equivalent 1200 H fps H fps H fps H fps H 48 3 1246 72 2 1246 96 1 1246 192 2 1246 2048 Max 2048 H fps H fps H fps H Fps H Full frame 28 7 2094 43 0...

Page 27: ...d in capital letters Separate between a command and a parameter by one space From the head of input character to the linefeed code r or n is analyzed as one command With 0x the parameter shall be anal...

Page 28: ...ned value r n Linefeed Returned value sp Prompt Space 5 r or n Make sure to input to indicate the end of the command 6 Initial settings Input INIT to restore to the initial settings Not saved at this...

Page 29: ...are different at normal mode and at vertical flip mode The number of data registerable by users is 128 Note Up to 32 points per CH CH Channel Images are processed by 4CH interleaves 0 0 1 0 2 0 3 0 0...

Page 30: ...ld not be deleted Additional registration of defected pixels by users Address 101 This is the function to register any defected pixels specifying its coordinate There are 2 parameters as commands The...

Page 31: ...ered by the user P Defects added by the user Parameter 3 Indicates the number of the registered defected pixels per CH Data at Ex factory Data registered by the user Parameter 4 Indicates the number o...

Page 32: ...SU sp 200 sp Write Address sp Data Returned value r n Returned value sp 2 Continuous data writing The maximum 4 of 1 byte 0 255 or 0x00 0xFF data can be set with space partitions If more numbers than...

Page 33: ...ity 4 0 Positive Trigger input 5 0 Camera Link CC1 FAST trigger mode selection 6 0 H sync mode Test pattern output 7 0 OFF Cursor indication 8 0 OFF Horizontal flip of the output image 11 0 Normal Ver...

Page 34: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 33 13 Sensor Optical Axis Accuracy...

Page 35: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 34 14 Dimensions...

Page 36: ...liberate or accidental misuse by the user or failure to observe the information contained in the instructions in this Product Specification and Operational Manual In case damages or losses are caused...

Reviews: