Example for Set Command
】
To set 30 to the address 30
[Send]
SU[sp]33[sp]30[¥r]or[¥n]
[Returned value] [¥r] [¥n]
[Linefeed]
[Returned value] >[sp]
[ Space]
(5)
[¥r]or[¥n]
Make sure to input to indicate the end of the command.
(6)
Licensing
This camera utilizes
μ
T-Kernel source code in accordance with μT-License of T-Engine forum (
www.t-engine.org
).
13.
Factory Settings
Function
Address
Data
Gain
1
0:
0dB
Shutter
2
0:
1/43s(OFF)
Trigger Shutter Mode
4
0:
Normal Shutter Mode (Trigger OFF)
Trigger Polarity
11
0:
Positive
Trigger Input
12
0:
Camera Link
(
CC1
)
Input
Output Data Selection
13
0:
8bit Output
Partial Scan Mode
15
0:
Full Frame Scan Mode
Vertical Flip
20
0:
OFF
Horizontal Flip
21
0:
OFF
Gamma Correction
23
0:
OFF
Binarization
24
0:
OFF
Shading Correction
26
0:
OFF
Defective Pixel Correction
30
1:
ON
Camera Mode
31
2:
Full Configuration Mode
Factory setting of the Switch at the back
Power Supply Selection (PoCL)
SW1
CL side