OPERATION. 

 

WARNING:

 Before applying power to the unit and switching on,  open the flap (3) on the top of 

the tank case and remove the screw cap (5). Keep this in a safe place and be sure to replace it 
during transit, or during long periods of non operation.  
 
1. Site the 

Strata

 in a well ventilated area.  

 
2. Remove the power cord from the cable tidy (8), and plug into IEC connector (9) ensuring first 

that the mains power switch  on the control panel (7)  is in the OFF position.   

 
3. Open flap (3) and remove the screw cap (5). Check the fluid  level to be within the lower and         

upper limits on the viewing window (4).  Refer to routine maintenance section of this manual 
if necessary.  OVERFILLING REDUCES PERFORMANCE and QUALITY OF MIST 
OUTPUT. 

 
4. If a mist is required in a specific area, such as a dance floor or a particular area on location,    
    CLOSE flap (3).  Turn mains power switch ON and mist will immediately start to emerge from 
    the side mist outlet (2).  
 
5. If a more ambient mist is required, leave flap (3) OPEN. Turn the mains power switch ON and        
    mist will immediately start to emerge upwards from the machine. 
 
6. Avoid operating the unit such that the room or venue becomes too heavy with mist. The    
    maximum acceptable level will be when the mist is just visible to the eye.  Please refer to the 
    useful tips section of this manual.  
 
 

 

 

 

WARNING

:   The  tank top has a pressure relief  bung (12) which is designed to prevent excess 

pressure building up in the tank, should the

 Strata

 be inadvertently switched on, with the screw 

cap still in place. This is for safety reasons only, and good operational practice should be used to 
ensure that the screw cap is always removed, prior to applying mains power. If the screw cap has 
been left on with the compressor running, the relief bung is likely to have blown out.  Simple 
refitting should restore the unit to full  specification, but thorough inspection is advisable to 
ensure the tank has not become distorted or the tank/lid rubber seal has ruptured, causing fluid 
leaks if  tippped.   
 

WARNING:

   Ensure the fan grill  (6) does not become blocked as this will lead to excessive 

internal temperatures and shorten the working life of the compressor. 

 
WARNING

   Always travel  the machine with the printed arrows pointing upwards. This is 

necessary to avoid accidental spillage of the fluid, although  short term tipping should not 
produce any leaks if the screw cap is securly fitted.  The 

Strata

  is equipped with a centrally 

placed carrying  handle,  provided for ease of moving  over short distances. 
 
 
 
_____________________________________________________________________________ 

 

Summary of Contents for Strata CS6

Page 1: ...any TV film promotional and touring rock shows It has been COSHH tested and approved for use in areas of public entertainment To ensure proper operation it is advisable that you read fully the followi...

Page 2: ...r window Level should be held within the range of this window Overfilling beyond the top of the indicator reduces performance and quality of mist output 5 Tank screw cap As a safety precaution always...

Page 3: ...ilter input via a Quick Connect socket 11 Air supply hose Free end connects directly to the air filter 10 input or via an extension hose 12 Safety bung Acts as a safety pressure relief valve to protec...

Page 4: ...en and yellow The wire which is colour coded blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is colour coded brown must be connected to the te...

Page 5: ...The maximum acceptable level will be when the mist is just visible to the eye Please refer to the useful tips section of this manual WARNING The tank top has a pressure relief bung 12 which is design...

Page 6: ...ff and then switch on again as necessary Do not just leave the machine running as this will result in too high a concentration of mist Since the desired effect will be dependent on the Directors requi...

Page 7: ...ining so the cup should contain no fluid when the unit is switched off Should automatic self draining not be appropriate then the locking nut on the cup base can be rotated to lock the drain closed In...

Page 8: ...also weaken the seal between the tank and it s lid As a safety feature the electric motor of the compressor provides its own temperature cut out Should this have come into operation the compressor wil...

Reviews: