 User Manual                                                                                            Page 4 

MAINS POWER 

 
The generator is designed to operate off a single phase 220-240V 50 Hz 

1

 AC supply capable of 

supplying a minimum of  300W.  A suitable IEC mains lead is supplied with the unit.   
 

WARNING

:  

THIS APPLIANCE MUST BE EARTHED.

 

 
The wires in the mains lead are colour coded in accordance with the following code: 
                                                      Green - and - yellow       Earth 
                                                      Blue                           :   Neutral 
                                                      Brown                        :   Live 
 
As the colours of the wires in the mains lead may not correspond with the coloured markings 
identifying the terminals in your plug, proceed as follows: 
 
The wire which is colour coded green-and-yellow must be connected to the terminals in the plug 
which is marked with the letter 'E' or by the earth symbol which is '    ', or which is coloured green 
or green-and-yellow. 
 
The wire which is colour coded blue must be connected to the terminal which is marked with the 
letter 'N' or coloured black. 
 
The wire which is colour coded brown must be connected to the terminal which is marked with 
the letter 'L', or coloured red. 
 
 

MAINS FUSING 

 
The mains power fuse is located underneath the IEC connector in a small carrier. Access is gained 
by first removing the IEC power cord and then using a flat blade to unclip and withdraw the fuse 
carrier.  The fuse is rated as 20mm 250vAC T3.15A. and a suitable spare is also provided. If this 
needs to be replaced it is essential for proper protection that it is replaced with one of the same 
specification. Should the fuse continue to blow, then internal damage has occurred and the whole 
unit must be returned to your dealer for service.  
 
 
 
 
_____________________________________________________________________________ 
 
 

 
 
 
 
 
 
 

                                                           

1

110v and 60Hz versions available to special order. 

Summary of Contents for Strata CS6

Page 1: ...any TV film promotional and touring rock shows It has been COSHH tested and approved for use in areas of public entertainment To ensure proper operation it is advisable that you read fully the followi...

Page 2: ...r window Level should be held within the range of this window Overfilling beyond the top of the indicator reduces performance and quality of mist output 5 Tank screw cap As a safety precaution always...

Page 3: ...ilter input via a Quick Connect socket 11 Air supply hose Free end connects directly to the air filter 10 input or via an extension hose 12 Safety bung Acts as a safety pressure relief valve to protec...

Page 4: ...en and yellow The wire which is colour coded blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is colour coded brown must be connected to the te...

Page 5: ...The maximum acceptable level will be when the mist is just visible to the eye Please refer to the useful tips section of this manual WARNING The tank top has a pressure relief bung 12 which is design...

Page 6: ...ff and then switch on again as necessary Do not just leave the machine running as this will result in too high a concentration of mist Since the desired effect will be dependent on the Directors requi...

Page 7: ...ining so the cup should contain no fluid when the unit is switched off Should automatic self draining not be appropriate then the locking nut on the cup base can be rotated to lock the drain closed In...

Page 8: ...also weaken the seal between the tank and it s lid As a safety feature the electric motor of the compressor provides its own temperature cut out Should this have come into operation the compressor wil...

Reviews: