Clamp size

 

Opening 1.5" (40mm) approx.

Diode Test

 

Test current of 0.3mA typical; Open circuit voltage 

1.5V DC typical.

Continuity Check

 

Threshold <40Ω; Test current < 0.5mA

Low Battery Indicator

 

“  

 ” is displayed

Over range Indicator

 

“OL” is displayed

Measurement Rate

 

2 per second, nominal

Input Impedance

 

10MΩ (VDC and VAC)

Display

 

6000 counts LCD

AC Current bandwidth

 

50-400Hz (AAC)

AC Voltage bandwidth

 

50-400Hz (VAC)

Operating Temperature

  41 to 104°F (5 to 40°C)

Storage Temperature

 

 -4 to 140°F (-20 to 60°C)

Operating Humidity

 

Max 80% up to 87°F (31°C) decreasing linearly 

to 50% at 104°F(40°C)

Storage Humidity

 

<80% 

Operating Altitude

 

7000ft. (2000meters) max.

Battery

 

One 9V  Battery 

Auto power OFF

 

approx. 15 minutes 

Dimensions / Weight

 

232x77x39mm / 271g

Safety / Approvals

 

This meter is UL and CUL approved and con-

forms to IEC61010-1 for Overvoltage Category  

CAT III 600V

Summary of Contents for DCL-620

Page 1: ...USER S MANUAL Clamp on Multimeter True RMS AC DCL 620 CIRCUIT TEST ELECTRONICS www circuittest com...

Page 2: ...Y NOTES Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set function switch OFF when the meter is not in use WARNINGS...

Page 3: ...is to be stored for long periods Always discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can...

Page 4: ...MODE button 11 LCD display 12 COM input jack 13 Positive input Jack AC Alternating current DC Direct currrent AUTO Autoranging REL Relative Diode test Continuity test HOLD Data Hold MAX Maximum readin...

Page 5: ...digits 60 00 VDC 600 0 VDC AC Voltage 50 400Hz 6 000 VAC 1 8 8 digits 60 00 VAC 600 0 VAC Resistance 600 0 1 0 4 digits 6 000K 1 5 2 digits 60 00K 600 0K 6 000M 2 5 3 digits 60 00M 3 5 5 digits Capac...

Page 6: ...ounts LCD AC Current bandwidth 50 400Hz AAC AC Voltage bandwidth 50 400Hz VAC Operating Temperature 41 to 104 F 5 to 40 C Storage Temperature 4 to 140 F 20 to 60 C Operating Humidity Max 80 up to 87 F...

Page 7: ...600A range 2 If the range of the measured is not known select the higher range first then move to the lower range if necessary 3 Press the trigger to open jaw Fully enclose one conductor to be measur...

Page 8: ...ad the resistance on the LCD display Diode and Continuity Measurements 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jac...

Page 9: ...icate Hz in the display 4 Insert the black lead banana plug into the negative COM jack and the red test lead banana plug into the positive Hz jack 5 Touch the test probe tips to the circuit under test...

Page 10: ...e detector light will illuminate NOTE The conductors in electrical cord sets are often twisted For best results rub the probe tip along a length of the cord to assure placing the tip in close proximit...

Page 11: ...ents For measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The Auto display indicator will turn off 2 Press the RANGE button to step thr...

Page 12: ...riginal purchaser that this product be free of defect in material or workmanship for a period of 2 years from the date of purchase Any product which has been subjected to misuse or accidental damage i...