background image

Einbau- und Betriebsanleitung 
Installation and Operating Instructions 
Instructions de montage et de service 

REact 30 - 8070

 

 

 

10/2018

 

 

The maximum stroke is 40 mm. The top position of the drive screw is shown in Image 8. 

 

8.2

 

Adjusting the force switch-off 

The force switch-off is factory preset (operational force/ closing force see: Technical Data, page 14).  
Adjustments are therefore not required.  

 

8.3

 

Adjusting the travel limit switch 

The travel limit switch E1 is wired in series with the force switch K1 for the OPEN direction (stem retracts) and E2 in series with force switch K2 for the CLOSED direction (stem 
extends). Adjusting stem E2 is used to limit travel in the CLOSED direction (stem extends) (Image 9). Adjusting stem E1 is used to limit travel in the OPEN direction (stem 

retracts) (Image 9). Here the actuating cams must not be moved beyond the switching point of the microswitch.  
If travel limit switches E1 and E2 are not required, they can be turned to the respective position using the adjusting stems. The actuator will then be switched off via the force 

switch-off. 
 

8.4

 

Adjusting additional limit switches 

The additional limit switches E3 and E4 can be used to signal any intermediate position; they can be adjusted using the adjusting stems (Image 9).  

 

8.5

 

Adjusting the potentiometer 

Upon delivery of the actuator and valve the potentiometer is factory preset (default: 10% of the max. Ohm of the potentiometer). 
 

Readjusting the potentiometer: 

 

Move the valve to the desired position.  

 

Loosen the grub screw to turn the adjusting ring on the potentiometer shaft (Image 10). The resistance of the potentiometer can be adjusted to any value (default: 10% of 
the max. Ohm of the potentiometer. 

Potentiometer combined with REtrans 2 W or REtrans 4 W 

 

Move the valve to the desired position 

 

additional adjustment see separate operating instructions: REtrans-8010. 

 

8.6

 

Adjusting and installing electronic positioners 

See separate operating instructions: REpos. 

The REpos mounts to the bracket with four fixing screws and onto the motor sheet with four fixing screws (Image 11). 
 

9

 

Heater 

The heater installation is shown in Image 12. 

The heater must be permanently connected to a power supply. 
The heater has a thermostat. This thermostat activates the heater once the surface temperature of the heater housing drops below 75°C. 

Please refer to the wiring diagram for the connection (Image 1). 
 

10

 

Position feedback module for the Repos (I/Y- Modul) 

The position feedback module mounts to the mounting bracket with four fixing screws (Image 13). 

Please refer to the wiring diagram for the connection, see separate operating instructions. 
 

11

 

RElog 

Mounts to the mounting angle with four fixing screws (Image 14). 

Please refer to the wiring diagram for the connection (Image 1). 
 

12

 

REtrans 

Mounts to the mounting bracket with four fixing screws (Image 15). 

Please refer to the wiring diagram for the connection, see separate operating instructions. 

 

13

 

Replacing parts 

13.1

 

Replacing the adapter board 

Attention!

  Follow safety regulations 

 
The actuator must be disconnected.  

 

Remove the carriage to replace the adapter board (Image 17 item 520). 

 

Remove the board bracket from the mounting plate. 

Summary of Contents for RTK REact 30 Series

Page 1: ...ings 5 4 Information 6 5 Electrical Connection 6 6 Manual hand wheel 6 7 Test run 6 8 Adjustment 6 9 Heater 7 10 Position feedback module for the REpos I Y Modul 7 11 RElog 7 12 REtrans 7 13 Replacing...

Page 2: ...Kegelkupplung auf die Kegelspindel schrauben Antrieb auf das Ventil setzen Federringe und Sechskantmuttern montieren Kegelkupplung und die Parallelf hrung mit 4 M6x25 Sechskantschrauben und Federringe...

Page 3: ...rbel kurbeln Bet tigung im Uhrzeigersinn Spindel wird ausgefahren Bet tigung gegen Uhrzeigersinn Spindel wird eingefahren Bild 5 Die Handverstellung ist auch unter Zuhilfenahme eines Akkuschraubers m...

Page 4: ...schluss erfolgt gem Anschlussplan Bild 1 10 Stellungsr ckmeldemodul f r REpos I Y Modul Das Stellungsr ckmeldemodul wird auf dem Befestigungswinkel mit vier Befestigungsschrauben befestigt Bild 13 Der...

Page 5: ...s nuts and spring washers Screw the cone clutch half way onto the plug stem Install parallel guide with two M6x16 bolts and spring washers Secure cone clutch with M4 grub screw Installation with pilla...

Page 6: ...torque 1 1 Nm Image 5 The cross section of the PE line must be at least the same as the cross section of the L N line connection The connection of the ground cable is to carry out in such a way that i...

Page 7: ...sition Loosen the grub screw to turn the adjusting ring on the potentiometer shaft Image 10 The resistance of the potentiometer can be adjusted to any value default 10 of the max Ohm of the potentiome...

Page 8: ...ent doit tre pr cis e lors de la commande d un entra nement Montage avec Joch Visser les crous hexagonaux DIN 439 M12 sur la broche de c ne longue Visser compl tement l embrayage c ne sur la broche de...

Page 9: ...erre La cosse de c ble avec le c ble de mise la terre est viss e avec une vis M4 et l aide d une bague ressort et deux rondelles la plaque du moteur couple de serrage 1 1 Nm ill 5 La section de la con...

Page 10: ...u servomoteur avec la vanne le potentiom tre pr sente d j les r glages d usine standard 10 de la valeur en ohm max du potentiom tre Ajustage ult rieur du potentiom tre placer l armature dans la posito...

Page 11: ...de force levier ill 17 pos 510 sur la pointe du support de platine Maintenir en place le contacteur de force levier l aide d un disque serrage rapide Monter le support de platine sur la plaque du mote...

Page 12: ...Kabeleinf hrung cable glands entr e c ble 4 x M 20 Gewicht weight poids 4 5 kg REact 30E Bei 60 Hz erh ht sich die Stellgeschwindigkeit und die Leistungsaufnahme um 20 For operation at 60 Hz the spee...

Page 13: ...tion sch ma de cablage E1 K2 K1 E4 E3 F1 F2 F3 F4 F5 F6 A1 A2 A3 PE Klemme 0 100 M POT 1 43 42 41 A2 A3 DA WA DZ WZ E2 M M1 M2 M3 Th Th CMotor Th Th 0 100 M POT 2 46 45 44 B4 B5 Hz E1 K2 K1 E4 E3 F1 F...

Page 14: ...eter Potentiom tre K2 Kraftschalter force switch contacteur de force Richtung ZU CLOSE direction direction ferm e HZ Heizung Heater Chauffage E1 Wegschalter limit switch contacteur de course Endlage A...

Page 15: ...ice REact 30 80150 10 2018 2 Technische Abbildungen Aufbau auf Armatur Joch Mounting on a valve yoke Aufbau auf Armatur S ulen Mounting on a valve pillars Bild 2 Bild 3 Einbau des Antriebes Installing...

Page 16: ...de service REact 30 80160 10 2018 Handbet tigung Manual operation fonctionnement manuel Kraftabschaltung Force switch Contacteur de force Bild 6 Bild 7 Einstellung des Hubes Stroke adjustment R glage...

Page 17: ...Instructions de montage et de service REact 30 80170 10 2018 Potentiometer Potentiom tre REpos Bild 10 Bild 11 Heizung Heater Chauffage Stellungsr ckmeldemodul f r REpos Position feedback module for...

Page 18: ...nstructions de montage et de service REact 30 80180 10 2018 RElog REtrans Bild 14 Bild 15 Montage der BLDC Motorgruppe Bild 16 1 4x Linsenschraube screw vis M4x10 2 BLDC Controller contr leur 3 4x Abs...

Page 19: ...Einbau und Betriebsanleitung Installation and Operating Instructions Instructions de montage et de service REact 30 80190 10 2018 4 Ersatzteilliste spare parts list liste de rechange Bild 17...

Page 20: ...Einbau und Betriebsanleitung Installation and Operating Instructions Instructions de montage et de service REact 30 80200 10 2018 Bild 18...

Page 21: ...Einbau und Betriebsanleitung Installation and Operating Instructions Instructions de montage et de service REact 30 80210 10 2018...

Page 22: ...rplatine Motor capacitor circuit board Moteur condensateur carte circuit CPLER301B209 230 V 0 74 mm s CPLER301B309 230 V 1 12 mm s CPLER201D109 115 V 0 28 mm s CPLER301D209 115 V 0 74 mm s CPLER301D30...

Page 23: ...e produit capteurs commutateurs r gulateurs transducteurs servomoteurs Produkttypen WT 11 DR 12 NI 13 NG 1 SG 2 RE MU 4 ST 51 REact Alle o g Produkte erf llen die EG Richtlinie f r EMV und die Nieders...

Page 24: ...bsanleitung Installation and Operating Instructions Instructions de montage et de service REact 30 80240 10 2018 Technische nderung vorbehalten Subject to technical alteration Sous r serve de modifica...

Reviews: