4
PUMP MODEL IDENTIFICATION
This instruction manual covers Imo C324AXFS-250/12004 pumps. Model of pump is identified on pump
nameplate. Refer to Figure 1 and Table 1 for instructional keys when using this manual.
C 324A X F X - 250 / 12500
Design
Modification
Special
Seal
Foot
Mounting
Pump
Series
Power Rotor
Diameter
Special
Customer
Requirements
Special
Pump Suffix
Number
Figure 1 – Definitions of Model Designators
ORDERING INSTRUCTIONS
When corresponding with Imo Pump regarding the C324AXFX-250/12005 pump, refer to pump nameplate,
this instruction manual, and assembly drawing as instructed below:
1. From pump nameplate, record pump model number, serial number and manufactured date.
2. Record instruction manual number, revision and date.
3. From instruction manual, record figure numbers that apply to replacement part(s).
4. From assembly drawing or parts list (see Figure 4A, 4B and Table 2) provide IDP number(s) and
names for replacement part(s).
5. Give above information to your Imo service representative.
Imo sales and service representatives are listed herein and in General Instruction Manual, SRM00046.
F. OPERATION
F.1 LIQUID
CAUTION
ATTENTION
Never operate with thin liquids such as solvents or water. Imo Pump has
approved the use of this pump model on a specific process type fluid.
F.2 OPERATING LIMITS
CAUTION
ATTENTION
Operating conditions, such as speed, fluid viscosity, temperature inlet pressure,
discharge pressure, filtration, duty cycle, drive type, mounting, etc., are
interrelated. Due to these variable conditions, specific application limits may be
different from that of operational limitations. Equipment must not be operated
without verifying system’s operating requirements are within pump’s capabilities.
Summary of Contents for IMO C324AXFX-12005