A.  GENERAL INSTRUCTIONS 

 
Instructions found herein cover disassembly, assembly and parts identification of C324AXFX-
250/12005 pump.

 

 

NOTE:  Individual contracts may have specific provisions that vary from this manual. Should any 

questions arise which may not be answered by these instructions, refer to General 
Instructions Manual, SRM00046, provided with your order.  For further detailed information 
and technical assistance please refer to Imo Pump, Technical/Customer Service 
Department, at (704) 289-6511. 

 

This manual cannot possibly cover every situation connected with installation, operation, inspection, and 
maintenance of equipment supplied.  Every effort was made to prepare text of manual so that engineering 
and design data is transformed into most easily understood wording.  Imo Pump must assume personnel 
assigned to operate and maintain supplied equipment and apply this instruction manual have sufficient 
technical knowledge and are experienced to apply sound safety and operational practices which may not 
be otherwise covered by this manual. 
 
In applications where equipment furnished by Imo Pump is to become part of processing machinery, these 
instructions should be thoroughly reviewed to ensure proper fit of said equipment into overall plant 
operational procedures. 

 

 

WARNING 

 

If installation, operation, and maintenance instructions are not correctly and strictly 
followed and observed, injury to personnel or serious damage to pump could result.  Imo 
Pump cannot accept responsibility for unsatisfactory performance or damage resulting 
from failure to comply with instructions. 

 
INTRODUCTION 
 

This instruction manual covers the C324AXFX-250/12005 pump.  

 

DESCRIPTION OF EQUIPMENT 
 

C324AXFX-250/12005  pump is a  positive  displacement, rotary screw pump consisting of precision bored 
housings that encloses a driven screw (power rotor) and two intermeshing following screws (idler rotors).  
These screws when rotating form a succession of closures or cavities.  As they rotate, fluid is moved axially 
from inlet port to outlet port in a continuous, uniform flow with minimum fluid pulsation and pump noise.  
Fluid flowing through pump provides lubrication to moving parts.  

 

Summary of Contents for IMO C324AXFX-12005

Page 1: ...FOR C324AXFX 250 12005 PUMP WARNING This Instruction Manual and General Instructions Manual SRM00046 should be read thoroughly prior to pump installation operation or maintenance of Pump SRM00110 Rev...

Page 2: ...persons Safety instructions where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of the pump and or protection of the pump...

Page 3: ...ational practices which may not be otherwise covered by this manual In applications where equipment furnished by Imo Pump is to become part of processing machinery these instructions should be thoroug...

Page 4: ...manual record figure numbers that apply to replacement part s 4 From assembly drawing or parts list see Figure 4A 4B and Table 2 provide IDP number s and names for replacement part s 5 Give above info...

Page 5: ...HEX CAP SCR 1 2 13 X 2 250 XX 0007 2 PP070AE PLUG 3 8 SHP 0008 1 S904ET 1X3 ROTOR HOUSING XX 0010 1 S904ET 1X4 ROTOR HOUSING XX 0011 2 S836BMX9 PIN STOP XX 0012 1 S838EJX3 SPACER 0013 1 DSC250HK ROTOR...

Page 6: ...astened joint is achieved for each application the following procedure is mandatory assembly practice Step 1 Using a suitable torque wrench install the fasteners in the mating piece until the Nylok in...

Page 7: ...ket head cap screws are engaged If for any reason centering clips are loosened prior to installation tighten cap screw finger tight then turn cap screw 1 8 turn roughly 20 in lbs 2 26 Nm Step 1 Assure...

Page 8: ...using wrap the rotors with a sling to prevent accidental dropping and to assist in holding the rotors in mesh for easy removal Step 5 Remove inboard end cover bolts 2 and remove inboard end cover 17 a...

Page 9: ...e end rotor housing 10 assuring that rotor housing end faces are fully seated against spacer 12 faces To assist in aligning housing bores install idler rotors 14 into idler bores Rotate rotor housings...

Page 10: ...sing a parallel bridge measure and record distances Q and X on inboard end cover 17 Subtract Q from X and add 009 23 mm 60 of gasket 4 thickness to this number Set adjusting screws to this distance fr...

Page 11: ...t 4 thickness to this number Make sure rotor housing 8 10 are seated against inboard housing adjusting screws Measure and record distance W from case 1 end flange to housing 10 end face If housing 10...

Page 12: ...ent is not achieved Step 6 Install Chesterton 180 cartridge mechanical seal 27 per instruction in Mechanical Seal Section of this manual See Section I 1 2 K INSTALLATION ALIGNMENT AND TROUBLESHOOTING...

Page 13: ...13...

Page 14: ...14 Circor 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 704 289 6511 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC all rights reserved...

Reviews: