Technical Data
ELECTRICAL DATA
Power supply
1P+N+PE / 3P+N+PE
Input voltage
/- 10% / /-10%
Frequency
50Hz / 60Hz
Protections (optional)
MCB (curve C) - includes shunt trip
DC 6mA leakage detector (MCB/RCBO with shunt trip
is required to open the circuit)
RCBO: RCD Type A + MCB - includes shunt trip
MODEL*
CONNECTORS
BY DEFAULT
OUTPUT
CURRENT
OUTPUT
POWER
MINIMUM
CABLE CROSS
SECTION**
eNext S
Type 2 Socket
32A
7,4kW
10mm
2
eNext T
Type 2 Socket
32A
22kW
10mm
2
Some models cannot include intern protections, at this point,
them shall be placed upstream with the same characteristics.
The national regulations must be taken into account.
(*) Please check availability with your local supplier
(**) This is the minimun cable cross section recommended for the maximum AC input
current. The final cross section must be calculated by a qualified technician taking
into account the specific conditions of installation.