Raption 150 Compact Installation Manual
Power input connection - Metal plate:
Steps:
1- Locate the power input entrance in the Charge Point bottom left part.
2- Assembly the metal plate provided. It is recommended to install a cable glands (not
supplied).
In order to make a secure cable installation it is necessary to use the metal plate
provided. In the case of not using this metal plate and any damage to internal
components arises due to the entry of dirt, animals or any other external element,
Circontrol will reject any warranty claim against the unit:
Step 1
Step 2
Note:
To ensure IP54 enclosure rating, it is needed to use foam insulation or another
similar material.