31
Raption 150 Compact Installation Manual
5
AC Power Supply
3P + N + PE
AC Voltage
400V AC +/- 10%
Maximum AC input current
237A
Required power supply capacity
163kVA
Power Factor
0.98
Efficiency
95 % at nominal output power
Frequency
50 / 60 Hz
Electrical input protection
Main breaker disconnection
Overcurrent protections
MCB
Safety protection
RCD Type B
Network connection
Ethernet 10/100BaseTX
Interface protocol
OCPP 1.5 or OCPP 1.6J SM
Compliance
CE / Combo-2
(DIN 70121; ISO15118)
IEC 61851-1; IEC 61851-23;
IEC 61851-21-2
CHAdeMO compatible
Enclosure rating
IP54 / IK10
Enclosure material
Stainless steel
Operating temperature
-30 ºC to +50 ºC
Ambient temperature storage
-40 ºC to +60 ºC
Operating humidity
5 % to 95 % Non-condensing
Socket protection
Locking System
RFID system
ISO / IEC14443-1/2/3
MIFARE Classic
Display HMI
8” colour antivandal touch screen
Power limit control
By software
DC cable length CCS
4 meters
DC cable length CHAdeMO
4 meters
Lights for status indication
RGB colour indicator
GENERAL SPECIFICATIONS