6.3 Error Message and Solutions
Item
Error Message
Descriptions
1.
COMMUNICATION FAIL
CAUSE:
Communication timeout. This error
message pops up if console and generator lose
communication for over 90 seconds.
SOLUTION:
- Check that the console and generator are
connected properly.
- If the connection is correct, please replace the
console or generator.
2.
DC BUS ERROR
CAUSE:
The generator cannot transform AC power
to DC power.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error
message pops up again, replace the generator.
3.
DCV VOLT OVERLOAD
CAUSE:
The voltage of DC generator is too high
(over 300V for 3 seconds). User may be peddling
too fast (normal peddling speed should be under
180 RPM).
SOLUTION:
- Stop peddling and wait
for the power to shut down.
- Peddle to power up the console. If the error
message pops up again, replace the generator.
4.
DCV VOLT OVERVOLT
CAUSE:
The voltage of DC generator is too high
(over 300V for 3 seconds). User may be peddling
too fast (normal peddling speed should be under
180 RPM).
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error
message pops up again, replace the generator.