background image

8. The operating safety of the pump is only guaranteed if the installation and service
instructions are correctly followed.
9. The limit values stated in the technical table should not be exceeded under any condition.
10. In the event of defective operation or fault, contact the technical support department of the
manufacturer or it

s nearest authorized agents.

11. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similarly qualified person to avoid a hazard.
12. The pump must not be used when people are in the water.
13. The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
14. Children should be under close supervision to prevent them from playing with the pump.
15. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
16. The pump must be protected from running dry.

Important Electrical Notice
The electrical installation is to be done by a licensed electrician.

Each pump requires a circuit breaker to separate the pump from the electrical supply.
The open contact distance of the circuit breaker is to be

no less than 3mm

The pump is to be supplied by an isolating transformer, or supplied through a residual current
device (RCD) with a rated residual current not exceeding 30mA.
Check the pumps name plate for the following: Voltage, Amp draw and Cycle.
The power cord, including the ground wire shall have a quality of

245 IEC66 (HO7RN-F)

for

models greater than 1kW power input.
For models less than

1kW

input the quality shall be of

245 IEC57 (H05RN-F).

All installations must comply with local codes, based on

IEC 364-7-702

requirements.

RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL.

INSTALLATION

Location
Note:

Do not install this pump within an outer enclosure or beneath the skirt of a hot tub or

spa unless marked accordingly.

Note:

Ensure that the pump is mechanically secured to the equipment pad.

Be sure the pump location meets the following requirements:

1. Install the pump as close to the pool or spa as possible. To reduce friction loss and improve
efficiency, use short, direct suction piping returns.
2. Install a minimum of 5 feet (1.52 meters) from the inside wall of the pool and spa. Canadian
installations require a minimum of 9.8 feet (3 meters) from pool water level.
3. Install the pump a minimum of 3 feet (9 meters) from the heater outlet.
4. Do not install the pump more than 10 feet (3.1 meters)above the water level.
5. Install the pump in a well ventilated location protected from excessive moisture (i.e., rain
gutter downspouts, sprinklers, etc.)

3

Summary of Contents for CSPPV711

Page 1: ...des and Ordinances Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer Th...

Page 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or instal...

Page 3: ...cured GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with...

Page 4: ...contact distance of the circuit breaker is to be no less than 3mm The pump is to be supplied by an isolating transformer or supplied through a residual current device RCD with a rated residual current...

Page 5: ...e 5 times the suction line pipe diameter See Figure 2 Example A 2 inch pipe requires a 10 inch 254 mm straight run in front of the suction inlet of the pump This will help the pump prime faster and la...

Page 6: ...xty 60 Seconds before servicing 2 Be sure that the supply voltage meets the requirements listed on the motor nameplate If these requirements are not met permanent motor damage may occur 3 For wiring s...

Page 7: ...or lug to the bonding structure Note When the pump is started and stopped by removing power with a relay or timer a two pole device should be used to apply and remove power to both POWER LINE TERMINAL...

Page 8: ...g RIGHT ARROW Moves the cursor right one digit when changing a setting LED Screen Composed of four digital tubes Display current time when in standby And display the current and running speed back and...

Page 9: ...When the pump is running ECO CLEAN BOOST press arrow buttons up or down to change the speed each press is for 50RPM It will save automatically no need to press ENTER 2 Switch ECO CLEAN BOOST during pu...

Page 10: ...pump will run on the selected speed 4 Pump Run under MODE1 MODE2 4 1 MODE 1 MODE2 Introduction MODE 1 MODE 2 16 hours running cycle 24 hours running cycle Stage Start Time Running Hour Default Speed Q...

Page 11: ...en the time is over 11 59 PM light will be lit AM light extinguished 3 Press ENTER to save and exit after start time set up To continue and adjust the running hour press MENU then use arrow buttons to...

Page 12: ...11...

Page 13: ...12 6 Control Panel Menu Structure...

Page 14: ...ker long enough for the keypad LEDs to turn off After power is reconnected if this error continues to reappear the drive may need service OVER VOLTAGE Indicates excessive supply voltage or and externa...

Page 15: ...s always adequate water in the filter tank before you start up If you are unable to prime the pump please see the trouble shooting guide ENSURE that all suction and discharge valves are open before yo...

Page 16: ...Turn off the voltage to the pump c Verify that there is no voltage in the circuits including ancillary devices and auxiliary circuits d Wait until motor stops completely The above list should be consi...

Page 17: ...attempt to examine all possible and imaginable cases of service and maintenance If supplementary instructions are required or if special problems arise do not hesitate to contact the distributor or to...

Page 18: ...ly 1 11 647254702 Pump Cover 1 12 65244015000 Gasket M10 10 13 65244032000 Spring Washer M10 6 14 65225003000 Screw 3 8 16 1 1 2 UNC 6 15 65023399000 Variable Speed 1 5HP Motor For CSPPV711 1 16 65221...

Page 19: ...embly Pump shaft is locked Check if the pump can be rotated by hand and remove any blockage Pump will not prime Suction air leak Make sure water level is correct through suction points Ensure baskets...

Page 20: ...running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temperature problem Installed in direct sunlight Shield from weather...

Page 21: ......