8. The operating safety of the pump is only guaranteed if the installation and service
instructions are correctly followed.
9. The limit values stated in the technical table should not be exceeded under any condition.
10. In the event of defective operation or fault, contact the technical support department of the
manufacturer or it
’
s nearest authorized agents.
11. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similarly qualified person to avoid a hazard.
12. The pump must not be used when people are in the water.
13. The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
14. Children should be under close supervision to prevent them from playing with the pump.
15. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
16. The pump must be protected from running dry.
Important Electrical Notice
The electrical installation is to be done by a licensed electrician.
Each pump requires a circuit breaker to separate the pump from the electrical supply.
The open contact distance of the circuit breaker is to be
no less than 3mm
The pump is to be supplied by an isolating transformer, or supplied through a residual current
device (RCD) with a rated residual current not exceeding 30mA.
Check the pumps name plate for the following: Voltage, Amp draw and Cycle.
The power cord, including the ground wire shall have a quality of
245 IEC66 (HO7RN-F)
for
models greater than 1kW power input.
For models less than
1kW
input the quality shall be of
245 IEC57 (H05RN-F).
All installations must comply with local codes, based on
IEC 364-7-702
requirements.
RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL.
INSTALLATION
Location
Note:
Do not install this pump within an outer enclosure or beneath the skirt of a hot tub or
spa unless marked accordingly.
Note:
Ensure that the pump is mechanically secured to the equipment pad.
Be sure the pump location meets the following requirements:
1. Install the pump as close to the pool or spa as possible. To reduce friction loss and improve
efficiency, use short, direct suction piping returns.
2. Install a minimum of 5 feet (1.52 meters) from the inside wall of the pool and spa. Canadian
installations require a minimum of 9.8 feet (3 meters) from pool water level.
3. Install the pump a minimum of 3 feet (9 meters) from the heater outlet.
4. Do not install the pump more than 10 feet (3.1 meters)above the water level.
5. Install the pump in a well ventilated location protected from excessive moisture (i.e., rain
gutter downspouts, sprinklers, etc.)
3