background image

W

ir

e

le

ss

 F

u

z

z

y

S

c

a

n

 

R

e

fe

re

n

c

e

 M

a

n

u

a

Configure Your FuzzyScan 

15 

Scan 

END

 

FuzzyScan will exit programming mode, and store all 

parameters in Flash Memory ASIC or non-volatile memory, 

then issue the completion beeping. 

 

Scan 

PROGRAM

 

FuzzyScan will enter programming mode, 

and inhibit all non-programming functions. 

 

Scan 

SYSLIST

 

FuzzyScan will list the product information and 

revision number to host via selected host interface, 

then issue the completion beeping. 

Scan 

M_DEFAULT

 

FuzzyScan will recover all programmable 

parameters into factory preset configurations, 

then issue the completion beeping. 

 

Program & End

Program & End

Program & End

Program & End    

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 

Please  note  that  the  FuzzyScan  will  take  3-4  seconds  to 
store  parameters  in  internal  Flash  Memory  ASIC  or 
non-volatile  memory  after  you  scan  the  “

END

”.  Please 

don’t

 turn  off the  power  before the  completion  beeping. It 

may destroy all configured parameters. 

 

System List, Group & Master Default

System List, Group & Master Default

System List, Group & Master Default

System List, Group & Master Default    

 

 

 

 

 

 

 

 

 

    
    
    
    
    
    

 

Summary of Contents for FuzzyScan F600BT Series

Page 1: ...WIRELESS IMAGER Reference Manual International Edition Rev B5...

Page 2: ...Page 48 Rename Auto Power Off Duration to Light Source On Time Add Extremely short option to Good Read Duration Page 49 Rename Presentation Scanning Auto sense to Presentation Auto sense Add Presentat...

Page 3: ...7 to 8 9 Rev B1 Mar 22 2011 Page 23 Add Code 39 Security Level Page 45 Add NAK Retry Count Add ACK NAK Transmission Indication Page 69 Add Numeric Bar Codes Page 73 Add Connecting Apple iOS Devices Qu...

Page 4: ...2 Page 49 Cancel 1 parameter of Code 39 Code 128 Emulation Disable standard code 39 emulation 0 Page 49 Change of default setting to Enable standard code 39 skip emulation in Code 39 Code 128 Emulatio...

Page 5: ...ce Warranty Cino warrants its products against defects in workmanship and materials from the date of shipment provided that the product is operated under normal and proper conditions The warranty prov...

Page 6: ...Wireless FuzzyScan Reference Manual MIC T401 LED Eye Safety IEC62471 Exempt group Laser Eye Safety IEC60825 1 Class 1...

Page 7: ...ing Function 10 Batch Scanning Inventory Mode 11 Configure Your FuzzyScan Bar Code Programming Manual 13 Programming Procedures 14 Host Interface Selection 18 Symbology Reading Control 19 Keyboard Int...

Page 8: ...nce but also delivers the convenience and freedom of mobility This document provides a quick reference for installation and operation purposes The complete documentation is available at www cino com t...

Page 9: ...r of the charging cradle turns steady blue Place the scanner on the cradle The status indicator of scanner will turn steady red if the battery is not fully charged When the battery is fully charged th...

Page 10: ...work with one smart cradle The smart cradle not only provides the Bluetooth radio link with the scanner but also offers the legacy cabled interfaces to the host device including USB HID USB COM PS 2...

Page 11: ...ady red Uninstall PAIR Mode Place the scanner on the smart cradle then you will hear one short beep to indicate the pairing process is activated The scanner will give continuous short clicks and the l...

Page 12: ...red Uninstall PICO Mode Place the scanner on the smart cradle then you will hear one short beep to indicate the pairing process is activated The scanner will give continuous short clicks and the link...

Page 13: ...en you use the Clone function Because the host interface related parameters can t be cloned to the paired scanner in disconnected status Save Configuration Clone The below host interface related param...

Page 14: ...INO FxxxBT xxxx and double click this HID service to establish the connection between the scanner and the remote host device The scanner will give 4 beeps in ascending tone to indicate the radio is co...

Page 15: ...scan 12 option codes and FIN command to confirm your inputs The scanner will give continuous short clicks and the link indicator of the scanner will flash blue quickly during the radio connecting pro...

Page 16: ...he list if the scanner is successfully discovered already Double click the CINO FxxxBT xxxx on the discovered Bluetooth devices If the PIN Code or Passkey is requested for security connection please e...

Page 17: ...ue blinks per 2 seconds Once the scanner is back to working range you will hear 4 beeps in ascending tone to indicate the radio connection rebuilt and the scanner will give 1 blue blink per 2 5 second...

Page 18: ...the batch scanning please scan the Exit Batch Scanning command Enter Batch Scanning Exit Batching Scanning How to Transmit Stored Data The scanner is preset to scan the Transmit Stored Data command to...

Page 19: ...data The quantity information will be stored into the memory storage together with the barcode data Quantity 0 Quantity 5 Quantity 3 Quantity 8 Quantity 1 Quantity 6 Quantity 4 Quantity 9 Quantity 2 Q...

Page 20: ...you need only turn over the programming page to find next desired programming family System Command System Command System Command System Command The System Command is the highest level bar code comman...

Page 21: ...mming procedures Each kind of programming procedure is listed in the following pages for your reference Please give careful attention to become familiar with each programming procedure If the programm...

Page 22: ...nterface then issue the completion beeping Scan M_DEFAULT FuzzyScan will recover all programmable parameters into factory preset configurations then issue the completion beeping Program End Program En...

Page 23: ...Yes Enter programming mode Select one of desired programming families Select one option code of desired parameter Want to select another programming family Exit programming mode Enter programming mod...

Page 24: ...ction If necessary Want to select another programming family Exit programming mode Scan PROGRAM Scan One of Family Codes Scan One of Option Codes Repeat Selection Scan END No Yes Scan FIN Enter progra...

Page 25: ...ace Selection MS MS MS MS MS MS MS MS MS MS IBM PS 2 25 30 series keyboard wedge interface Standard TTL RS 232 peer to peer serial Wand emulation USB Com Port Emulation PS 2 DOS V direct link keyboard...

Page 26: ...man Postal Code default M IATA default O Code 11 default P MSI Plessey default R UK Plessey default S Telepen default T GS1 DataBar default X UPC E default E EAN 8 default N Trioptic Code 39 Default W...

Page 27: ...ymbology ID Transmission SS SS SS SS SS SS SS Disable symbology ID transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix...

Page 28: ...Plessey Telepen GS1 DataBar RSS 14 IATA PDF417 Micro PDF417 Codablock F Korea Post Code 00 01 02 03 04 05 06 07 47 08 38 48 58 68 09 10 11 12 13 14 15 17 18 21 If your application is known you may sel...

Page 29: ...e Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 bufferi...

Page 30: ...0 If you are experiencing misread of poorly printed or serious out of spec bar codes in level 1 please select level 0 Level 1 If you are experiencing misread of poorly printed or out of spec bar code...

Page 31: ...smission Enable abcd abcd start stop symbol transmission Enable ABCD TN E start stop symbol transmission Enable abcd tn e start stop symbol transmission Disable check digit verification Enable check d...

Page 32: ...gy Reading Control Codabar NW 7 Setting F_DEFAULT Family Code Selection P C Parameter Selection Option Code Codabar Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in A...

Page 33: ...leading 1 portion Enable UPC leading 1 portion 0 1 2 3 4 5 6 7 8 9 A B C D E F When enable UPC E expansion the UPC E decoded data will be converted to UPC A format and affected by related setting such...

Page 34: ...codes Level 0 If you are experiencing misread of poorly printed or out of spec bar codes especially in characters 1 2 7 and 8 in level 1 please select level 0 Selection of this security level may sign...

Page 35: ...AN with only 5 supplement digits Select EAN with 2 5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN Addenda Separator Off EAN Addenda Separator On 0...

Page 36: ...n characters 1 2 7 and 8 in level 1 please select level 0 Selection of this security level may significantly impair the decoding ability of the scanner Level 1 This is the default setting which allows...

Page 37: ...ion Option Code UCC Coupon Extended Code SS SS Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code 0 1 UCC Coupon Extended Code When UCC coupon extended code function is enabled scanner d...

Page 38: ...ng digit verification only Enable CPN checking digit verification only Enable CPN Airline and S N check digit verification Disable check digit transmission Enable check digit transmission Disable star...

Page 39: ...sable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 9 Code 25 Family Min Length SS MS Default 04 01 Maximum Scan 2 digits from the option code chart in Appendix then Fuzzy...

Page 40: ...Appendix then FuzzyScan will terminate this selection automatically FIN 2 digits Code 11 Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then FuzzyScan will...

Page 41: ...Select MOD 10 10 check digit Select MOD 11 10 check digit Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 MSI Plessey Min Length SS MS Default 04 01 Maximum Scan 2 digi...

Page 42: ...1 128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On 0 1 2 3 4 5 Code 128 EAN 128 Min Length SS MS Default 01 01 Maximum Scan 2 digits fr...

Page 43: ...t UK Plessey CLSI Format Disable Convert X to A F Enable Convert X to A F Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 UK Plessey Min Length SS MS Default 04 01 Max...

Page 44: ...umeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 Telepen Min Length SS MS Default 04 01 Maximum Scan 2 digits from the option cod...

Page 45: ...DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded 0 1 2 3 4 5 GS1 DataBar Min Length SS MS Default 04 01 Maximum Only available for Expanded GS1 Databar Scan 2 digits from the o...

Page 46: ...UPC always linked 0 1 2 3 PDF417 MicroPDF417 Setting SS SS SS SS Disable PDF417 Enable PDF417 Disable MicroPDF417 Enable MicroPDF417 0 1 2 3 Codablock F Setting SS SS Disable Enable 0 1 Korea Post Co...

Page 47: ...ds QWERTY Denmark QWERTY Belgium AZERTY Switzerland Germany QWERTY Iceland QWERTY Japan DOS V Czech QWERTY 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 Please refer to the ASCII HEX Table lis...

Page 48: ...ff State Caps Lock On State Auto Detect PC AT PS 2 Keyboard Replacement and DOS V Machines only 0 1 2 Caps Lock Release Control SS SS Caps Lock On Caps Off Caps Lock On Shift Off 0 1 The function of C...

Page 49: ...ally FIN 2 digits Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications process the incoming data on time Intercharacter Delay is a...

Page 50: ...as keyboard function code output Ctrl Output Refer to Appendix Keyboard Function Code Table for details 0 1 Key Pad Emulation SS SS Disable key pad emulation Enable numeric output as key pad Num Lock...

Page 51: ...S SS SS SS SS SS MS None CR 0DH LF 0AH CRLF 0D0AH TAB 09H SPACE 20H User defined character 1 character 0 1 2 3 4 5 6 00 7F Preamble SS MS None 1 15 characters Maximum 15 character input scan FIN to te...

Page 52: ...lly FIN 2 digits Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications process the incoming data on time Intercharacter Delay is a t...

Page 53: ...ce 2 SPP master or slave mode NAK Retry Count After transmitting data the scanner expects a NAK response from the host up to the preset Serial Response Time out If the scanner doesn t get a response t...

Page 54: ...Wireless FuzzyScan Reference Manual Configure Your FuzzyScan 47 Enable There s a specific LED and beeping indication for this setting...

Page 55: ...00 BPS 2400 BPS 1200 BPS 57 6K BPS 115 2K BPS 0 1 2 3 4 5 8 9 Data Frame SS SS SS SS SS SS SS SS 8 None 1 8 Odd 1 8 Even 1 8 Space 1 8 Mark 1 8 None 2 7 Odd 1 7 Even 1 7 Space 1 7 Mark 1 7 None 2 7 Od...

Page 56: ...ta transmission 0 1 2 3 4 5 6 Module Time SS SS SS Extremely short Short Medium Long Time base of minimum narrow bar 0 1 2 3 Narrow Wide Ratio SS SS SS 1 2 1 2 5 1 3 0 1 2 Code 39 Code 128 Emulation S...

Page 57: ...r to turn on the light source of the scanner before scanning the bar code Presentation Mode Auto Detection Presentation mode uses ambient light to detect the bar codes The light source is off until th...

Page 58: ...tone high Buzzer tone extremely high Power on beep No power on beep 0 1 2 3 4 5 6 Power On Indicator SS SS SS Disable LED off LED steady on LED flash 0 1 2 Good Read Indicator SS SS Disable Enable 0 1...

Page 59: ...put as Dollar sign output as 0 1 2 3 4 Redundancy SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading 0 1 2 3 4 5 Scan Rate Control SS SS Dynamic Fixed 0 1...

Page 60: ...dium time out Long time out Force verification 0 1 2 3 4 5 Good Read Delay SS SS SS SS SS SS SS None 200 msec 500 msec 1 sec 1 5 sec 2 sec 3 sec 0 1 2 3 4 5 6 The Reread Delay Double Scan Verification...

Page 61: ...t Source On Time is a pre defined light source time out counter for Alternative Mode Presentation Mode and Level Mode The scanner keeps the light source on till the pre defined light source on time is...

Page 62: ...wer Off Timeout is a pre defined duration for scanner s light source on time when the scanner is placed on SmartStand While the scanner is placed on SmartStand the scanner s will be switched from hand...

Page 63: ...rcode Forward reading Indication SS SS MS None S User defined character 1 character 0 1 2 00 7F 1D Barcode Backward reading Indication SS SS MS None X User defined character 1 character 0 1 2 00 7F 1D...

Page 64: ...0 FIN 2 digits Out of range Scanning When radio link is built between the scanner and remote host device the scanner will transmit each scanned data right after scanning the barcode data However the s...

Page 65: ...e is activated the radio link will be disconnected once you enter batching scanning The radio link will be resumed when you transmit the stored data or exit batch scanning The Stored Data Transmission...

Page 66: ...O modes 0 1 2 The Field Delimiter is used to separate the specific information and scanned data into two fields You can choose desired delimiter format The Batch Data Quantity Output Format If you wan...

Page 67: ...SS SS Disable Enable 0 1 The default Bluetooth Device Name is CINO FxxxBT xxxx you will be able to change the device name by scanning HEX values 1 16 characters The default Bluetooth PIN Code is 0000...

Page 68: ...SS SS Disable Enable 0 1 Bluetooth Power Saving Mode SS SS Disable Enable 0 1 The HID Link Quality Setting While using the HID radio link mode some errors may occur during the data transmission when...

Page 69: ...mbology ID transmission 0 1 2 3 4 5 6 DataWizard is the most powerful Artificial Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers Through Data...

Page 70: ...rs FIN 4th Insertion SS DS Disable Enable 2 digits identified position max 3 insertion characters FIN 2 digits position 1 3 characters FIN The Data Formatter is used to edit the scanned raw data prior...

Page 71: ...haracter SS DS Disable Enable 2 digits checking position 1 identified character FIN 2 digits position 00 7F The Data Verifier is used to provide advanced verification for error free scanning and to wo...

Page 72: ...ed position 1 replacement character FIN 2 digits position 00 7F The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you t...

Page 73: ...tted data excluded the data of identified position Transmitted data included the data of identified position 0 1 The Data Organizer is used to edit the scanned raw data prior to transmitting the data...

Page 74: ...rea Post Code 26 Position Calculation Position Calculation Position Calculation Position Calculation Data Formatter If there is a 5 character input data string refer to the following to calculate the...

Page 75: ...scan FIN Finish code to terminate this selection Scan 3rd Insertion and set the identified position to 16 then inserted character to 09 In the final you must scan FIN Finish code to terminate this se...

Page 76: ...N 8 bar code 49123562 with 5 supplement 12345 is transmitted as E449123562 E212345 Code 128 B m Code 93 Code 93 H G m Code 128 GS1 128 C C 1 Code 11 Code 11 P H m Codabar Codabar NW 7 D F m MSI Plesse...

Page 77: ...25 EM 19H END Edit 10 LF 0AH F2 26 SUB 1AH PAGE UP Edit 11 VT 0BH F3 27 ESC 1BH PAGE DOWN Edit 12 FF 0CH F4 28 FS 1CH UP Edit 13 CR 0DH ENTER CR 29 GS 1DH DOWN Edit 14 SO 0EH F5 30 RS 1EH LEFT Edit 1...

Page 78: ...this family Refer to the Hex ASCII Table you will find the HEX value of is 24 Scan the option code 2 listed on the fold out back cover Scan the option code 4 listed on the fold out back cover Scan the...

Page 79: ...Wireless FuzzyScan Reference Manual Appendix 72 Numeric Bar Codes 0 5 3 8 1 6 4 9 2 7...

Page 80: ...Wireless FuzzyScan Reference Manual Appendix 73 Link Mode Quick Set Uninstall SPP Slave Mode PAIR Mode HID Mode SPP Master Mode PICO Mode Operation Mode Quick Set Trigger Mode Presentation Mode...

Page 81: ...e Manual Appendix 74 Host Interface Quick Set Work with Smart Cradle only RS232 Serial PS 2 DOS V KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS 2 DOS V KBW Turbo Mode USB HID Turbo M...

Page 82: ...Wireless FuzzyScan Reference Manual Appendix 75 Option Codes 0 8 4 C 1 9 5 D 2 A 6 E 3 B 7 F FIN Finish END Exit...

Page 83: ...x 76 Connecting Apple iOS Devices Quick Sets Enable Variable PIN Code Disable Variable PIN Code BT PIN Code Please refer to Quick Reference Guide of Connecting FuzzyScan Bluetooth Cordless Scanners wi...

Page 84: ...scanning Master Default command the scanner will remain the pre set parameters of Host Interface Selection Keyboard Interface Control except Record Suffix Preamble Postamble Serial Interface Control...

Page 85: ...nder charging on cradle Steady red Off Fully charged on cradle 1 green blink at regular interval Off Under batch scanning 1 green blink per 2 5 sec Off Pair failure Steady red 2 Di do Di do beeps Out...

Page 86: ...beeps Smart Cradle Upgrade State Off Steady red Short clicks Uninstall state Off Alternative red green blinks Off Radio Connected Steady blue Steady Green Off PICO Mode Radio Disconnected Off Steady...

Page 87: ...CINO GROUP FuzzyScan Wireless Reference Manual PC WORTH INT L CO LTD www cino com tw...