Configure Your FuzzyScan
53
PROGRAM
Operation Control
♦
♦
♦
♦
Delay Setting
♦
♦
♦
♦
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
Reread Delay
(Double Scan Verification)
SS
SS
SS
SS
SS
SS
Disable
Immediate time out
Short time out
Medium time out
Long time out
Force verification
0
1
2
3
4
5
Good Read Delay
SS
SS
SS
SS
SS
SS
SS
None
200 msec.
500 msec.
1 sec.
1.5 sec.
2 sec.
3 sec.
0
1
2
3
4
5
6
The
Reread Delay (Double Scan Verification)
is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification
will not allow reading of the same bar code twice.
This
Good Read Delay
is the minimum amount of time before the scanner can read another bar code.