Configure Your FuzzyScan
68
Programming Procedure
Programming Procedure
Programming Procedure
Programming Procedure
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to “
48
”
(Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to “
16
”.
Scan “1st Identified Character” and set the identified
position to “
00
”, then set the identified character to “
39
”
(Hex Code of 9).
[Data Formatter]
Scan “Formatter Control” and set bar code symbology to
“
48
”.
Scan 1st Insertion” and set the identified position to “
06
”,
then inserted characters to “
09
” (Hex Code of TAB), “
53
”
(Hex Code of S), “
4E
” (Hex Code of N).
Scan “2nd Insertion” and set the identified position to “
12
”,
then inserted character to “
09
”. In the final, you must scan
“
FIN
” (Finish) code to terminate this selection.
Scan “3rd Insertion” and set the identified position to “
16
”,
then inserted character to “
09
”. In the final, you must scan
“
FIN
” (Finish) code to terminate this selection.
[Data Replacer]
Scan “Replacer Control” and set bar code symbology
to “
48
”.
Scan “1st Replacement” and set the identified position
to “
00
”, then replaced character to “
41
” (Hex Code of
A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology
to “
48
”.
Scan “1st Organization” and set the identified position
to “
16
”, then set the data transmission to “
0
” (forward).
Scan “2nd Organization” and set the identified position
to “
17
”, then set the data transmission to “
1
”
(backward).
Scan “
END
” (Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the
preset working flow as below:
Verifier
Formatter
Replacer
Organizer
So when you set the identified position in Data Organizer,
you must consider the inserted data which you already set
via Data Formatter.