Configure Your FuzzyScan 

15 

 

PROGRAM 

Symbology Reading Control 

 Readable Bar Code Setting 



 

F_DEFAULT   

Family Code Selection 

P.C 

Parameter Selection 

Option Code 

Readable Symbology Setting 

CS 
CS 
CS 
CS 
CS 
CS 
CS 

Australian Post 
British Post 
Intelligent Mail barcode 
Japanese Post 
KIX Post 
Planet Code 
Postnet

 

B0 
B1 
B3 
B4 
B5 
B6 
B8

 

 

If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add 
the “

Symbology ID

” into the transmitted data is also helpful to identify the specific symbology. 

 

Above symbologies marketed with * are enabled as default. When you select “Auto”, the scanner only reads those symbologies marked with 

*.

   

 

"Popular 1D" includes "Code 128", "GSA-128", "UPC-A", "UPC-E", "EAN-13", "EAN-8", "Codabar/NW-7", "Code 39", " Interleaved 2 of 5", "Code 93", "GS1 DataBar 
(RSS-14)". 

 

When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include start/stop characters. 

Summary of Contents for FuzzyScan A670 Series

Page 1: ...International Edition Rev D14...

Page 2: ...DF417 Codablock F Korea Post Code Modify Appendix Symbology ID Table Rev B3 Oct 16 2009 Add Host Interface Selection IBM PS 2 25 30 series keyboard wedge interface Add Operation Control Presentation S...

Page 3: ...11 Rename Symbology Reading Control UCC EAN 128 to GS1 128 Rename Serial Interface Control ACK NAK Transmission Indication to ACK Indication Modify Serial Interface Control ACK Indication and Serial r...

Page 4: ...MaxiCode Setting Rev D7 Aug 17 2015 Add Host Interface Selection USB EFT Terminal Mode Rev D8 Dec 25 2015 Revise Revision History Add Getting Started A670 series scanner Rev D9 May 31 2016 Add Operati...

Page 5: ...ects in workmanship and materials from the date of shipment provided that the product is operated under normal and proper conditions The warranty provisions and durations are furnished by different wa...

Page 6: ...l 5 Programming Procedures 6 Host Interface Selection 10 Symbology Reading Control 11 Keyboard Interface Control 43 Serial Interface Control 48 Wand Laser Emulation Control 52 Operation Control 54 Con...

Page 7: ...ger The Antimicrobial models are available for A770 L780 and F780 series scanners which are equipped with Disinfectant ready Housing and Vibrator Moreover the option of Vibrator is available for all o...

Page 8: ...FuzzyScan Programming Manual Getting Started 2 F790 F780 L780 Series F560 Series A670 F680 L680 Series Power Indicator Status Indicator Trigger Scan Window Beeper Cable Release Hole...

Page 9: ...l interfaces Please choose your desired interface cable then plug it into the cable interface port of the scanner and connect it to the host If you would like to remove the cable please straighten one...

Page 10: ...ners Hand free SmartStand SmartStand is specifically designed for hand free applications to maximize user s comfort and productivity You can adjust the scanner holder to desired position for optimized...

Page 11: ...to change the programming family for multiple settings you need only turn over the programming page to find next desired programming family System Command The System Command is the highest level bar...

Page 12: ...gramming procedures Each kind of programming procedure is listed in the following pages for your reference Please give careful attention to become familiar with each programming procedure If the progr...

Page 13: ...duct information and revision number to host via selected host interface then issue the completion beeping Scan M_DEFAULT FuzzyScan will recover all programmable parameters into factory preset configu...

Page 14: ...ect one option code of desired parameter Want to select another programming family Exit programming mode Enter programming mode Select one of desired programming families 1 Select one or several optio...

Page 15: ...m ode Scan PRO G RAM Scan O ne of Fam ily Codes Scan O ne of O ption Codes Repeat Selection Scan END No Yes Scan FIN Enter program m ing m ode Select one of desired program m ing fam ilies Select seve...

Page 16: ...TTL RS 232 peer to peer serial Wand Emulation USB Com Port Emulation PS 2 DOS V direct link keyboard replacement PS 2 DOS V keyboard wedge turbo mode PS 2 DOS V keyboard wedge standard mode Laser emu...

Page 17: ...fault S Telepen default T GS1 DataBar default X UPC E default E EAN 8 default N Trioptic Code 39 default W UCC Coupon Extended Code default Z PDF417 Micro PDF417 default V Codablock F default Y Code 1...

Page 18: ...e Symbol ID 1 character DS Aztec Code default e Chinese Sensible default f Australian Post default g British Post default h Intelligent Mail USPS 4CB One Code default j Japan Post default k Netherland...

Page 19: ...ology ID Transmission SS SS SS SS SS SS SS Disable symbology ID transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CIN...

Page 20: ...NW 7 Code 39 Trioptic Code 39 Standard Industrial 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 China Postal Code Germany Postal Code Code 93 Code 11 MSI Plessey UK Plessey Telepen GS1 DataBar RSS 14 IATA P...

Page 21: ...mbologies only to increase the reading speed and decrease the possibility of reading error Furthermore to add the Symbology ID into the transmitted data is also helpful to identify the specific symbol...

Page 22: ...de 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering E...

Page 23: ...If you are experiencing misread of poorly printed or serious out of spec bar codes in level 1 please select level 0 Level 1 If you are experiencing misread of poorly printed or out of spec bar codes i...

Page 24: ...ol transmission Enable abcd tn e start stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission 0 1 2...

Page 25: ...leading 1 portion Enable UPC leading 1 portion 0 1 2 3 4 5 6 7 8 9 A B C D E F When enable UPC E expansion the UPC E decoded data will be converted to UPC A format and affected by related setting suc...

Page 26: ...only 5 supplement digits Select UPC with 2 5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separato...

Page 27: ...pec UPC EAN bar codes Level 2 If you are experiencing misread of poorly printed soiled or damage bar codes in level 1 please select level 2 This is the most aggressive setting and may increase the mis...

Page 28: ...mission Disable ISBN ISSN Conversion reading check Enable ISBN ISSN Conversion reading check 0 1 2 3 4 5 6 7 8 9 A B EAN Supplement Setting SS SS SS SS SS SS SS SS Select EAN without supplement digits...

Page 29: ...d It is helpful when decoding a mix of UPC EAN symbols with and without supplement digits This function is effective when you select UPC EAN with only 2 supplement digits UPC EAN with only 5 supplemen...

Page 30: ...aracters 1 2 7 and 8 in level 1 please select level 0 Selection of this security level may significantly impair the decoding ability of the scanner Level 1 This is the default setting which allows the...

Page 31: ...Option Code UCC Coupon Extended Code SS SS Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code 0 1 UCC Coupon Extended Code When UCC coupon extended code function is enabled scanner deco...

Page 32: ...igit verification only Enable CPN checking digit verification only Enable CPN Airline and S N check digit verification Disable check digit transmission Enable check digit transmission Disable start st...

Page 33: ...e check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 9 Code 25 Family Min Length SS MS Default 04 01 Maximum Scan 2 digits from the option code chart in Appendix then FuzzyScan...

Page 34: ...endix then FuzzyScan will terminate this selection automatically FIN 2 digits Code 11 Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then FuzzyScan will te...

Page 35: ...ect MOD 10 10 check digit Select MOD 11 10 check digit Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 MSI Plessey Min Length SS MS Default 04 01 Maximum Scan 2 digits f...

Page 36: ...is selection automatically FIN 2 digits Code 128 Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically...

Page 37: ...ng SS SS Disable GS1 128 Enable GS1 128 0 1 GS1 128 Min Length SS MS Default 01 01 Maximum Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatical...

Page 38: ...Plessey CLSI Format Disable Convert X to A F Enable Convert X to A F Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 UK Plessey Min Length SS MS Default 04 01 Maximum...

Page 39: ...ic mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 Telepen Min Length SS MS Default 04 01 Maximum Scan 2 digits from the option code ch...

Page 40: ...art in Appendix then FuzzyScan will terminate this selection automatically FIN 2 digits GS1 DataBar Max Length SS MS Default 74 74 Minimum Only available for GS1 DataBar Expanded Scan 2 digits from th...

Page 41: ...odes UPC Composite Mode UPC never linked UPC Composite Mode UPC always linked If UPC Composite Mode UPC never linked is selected UPC barcodes are transmitted whether MicroPDF417 symbol is detected or...

Page 42: ...tically FIN 3 digits Code 16K Max Length SS MS Default 160 160 Minimum Scan 3 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically FIN 3 digits Code...

Page 43: ...nd Enable QR Code Append Disable QR Code Inverse Reading Enable QR Code Inverse Reading Auto detect QR Code Inverse Reading 0 1 2 3 4 5 6 7 8 QR Code Min Length SS MS Default 01 01 Maximum Scan 4 digi...

Page 44: ...chart in Appendix then FuzzyScan will terminate this selection automatically FIN 4 digits Data Matrix Max Length SS MS Default 3116 3116 Minimum Scan 4 digits from the option code chart in Appendix t...

Page 45: ...SS SS Disable MaxiCode Enable MaxiCode 0 1 MaxiCode Min Length SS MS Default 01 01 Maximum Scan 3 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatica...

Page 46: ...SS Disable Aztec Code Enable Aztec Code 0 1 Aztec Code Min Length SS MS Default 01 01 Maximum Scan 4 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automat...

Page 47: ...e 0 1 2 3 4 5 US Planet Setting SS SS SS SS Disable US Planet Enable US Planet Disable Check Digit Transmission Enable Check Digit Transmission 0 1 2 3 US Postnet Setting SS SS SS SS Disable US Postne...

Page 48: ...ting F_DEFAULT Family Code Selection P C Parameter Selection Option Code Netherlands KIX Code Setting SS SS Disable Netherlands KIX Code Enable Netherlands KIX Code 0 1 Intelligent Mail Setting USPS 4...

Page 49: ...WERTY Denmark QWERTY Belgium AZERTY Switzerland Germany QWERTZ Iceland QWERTY Japan DOS V Czech QWERTY 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 Please refer to the ASCII HEX Table listed...

Page 50: ...cter 0 1 2 3 4 5 00 7F Preamble SS MS None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7F FIN Postamble SS MS None 1 15 characters Maximum 15 character input...

Page 51: ...Caps Lock Control and Key Pad Emulation are only available for IBM PC AT PS VP PS 2 series personal computers and compatible machines While selecting the other host interfaces these selections don t p...

Page 52: ...ix then FuzzyScan will terminate this selection automatically FIN 2 digits Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications pro...

Page 53: ...Keyboard Function Code Table for details 0 1 Key Pad Emulation SS SS Disable key pad emulation Enable numeric output as key pad Num Lock On output 0 1 Upper Lower Case SS SS SS SS Normal case neglect...

Page 54: ...scan FIN to terminate this selection FIN 00 7F FIN Postamble SS MS None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7F FIN FNC1 Symbol Char Transmit SS SS Di...

Page 55: ...yScan will terminate this selection automatically FIN 2 digits Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications process the inc...

Page 56: ...the host up to the preset Serial Response Time out If the scanner doesn t get a response the scanner will issue an error indication and discard the data When a NAK is received the scanner transmits th...

Page 57: ...800 BPS 2400 BPS 1200 BPS 57 6K BPS 115 2K BPS 0 1 2 3 4 5 8 9 Data Frame SS SS SS SS SS SS SS SS 8 None 1 8 Odd 1 8 Even 1 8 Space 1 8 Mark 1 8 None 2 7 Odd 1 7 Even 1 7 Space 1 7 Mark 1 7 None 2 7 O...

Page 58: ...0Vdc on Bar high level on Space Determine the output voltage level for both bar and space 0 1 Initial Signal State SS SS High Level 5Vdc Low Level 0Vdc Determine the initial state of output voltage l...

Page 59: ...on Enable standard Code 39 replace emulation Enable Full ASCII Code 39 emulation Enable Code 128 emulation 0 1 2 3 4 Code 39 Skip When this option is selected all scanned data will be translated as St...

Page 60: ...u do not have to press the trigger frequently it is very convenient for multiple scanning Flash Mode Pulse Driven Reading The scanner flashes the light source of the scanner without using the trigger...

Page 61: ...hand held scanning to hands free scanning automatically Three hands scanning modes are available You are recommended to use flash mode or force mode while under insufficient ambient light Scan Rate C...

Page 62: ...ble for L Series 0 1 LED Illumination Delay SS SS SS SS SS 100 ms 150 ms 200 ms 250 ms 300 ms Only available for L Series 0 1 2 3 4 LED Illumination Control When you enable always on the LED illuminat...

Page 63: ...Forward reading Indication SS SS MS None S User defined character 1 character 0 1 2 00 7F 1D Barcode Backward reading Indication SS SS MS None X User defined character 1 character 0 1 2 00 7F 1D Barco...

Page 64: ...8 Presentation Control SS SS Presentation mode Force mode 0 1 Illumination Control SS SS Disable Enable 0 1 Presentation Background Lighting SS SS LEDs Off LEDs On 0 1 Hand Held Mode Low power mode Tr...

Page 65: ...Enable in Hand Held mode Disable in Hand Free mode Enable in Hand Free mode 0 1 2 3 The Aiming Control is only available for trigger mode In Intelligent Aiming the aiming light is turned on when the...

Page 66: ...SS SS SS SS Disable in Hand Held Mode Enable in Hand Held Mode Disable in Hand Free Mode Enable in Hand free Mode 0 1 2 3 Unique Bar Code Reporting SS SS Disable Enable 0 1 Center Alignment When this...

Page 67: ...ot available when Multiple Read Mode or Center Alignment is turned on Batch Reading Rule To set the Batch Reading rule 1 Scan the PROGRAM symbol 2 Scan the Batch Reading symbol Family Code 3 Use the O...

Page 68: ...to find the Hex value that represents the character s you want to match Use the Option Code to scan the alphanumeric combination that represents the ASCII characters You can match up to 4 characters w...

Page 69: ...for Code 39 9999 all lengths 42 Start character that must match for Code 39 42h B FF End of second code 09 Code identifier of Code 93 9999 Code length that must match for Code 93 9999 all lengths 43 S...

Page 70: ...g all character Also indicate end of second code 09 Code identifier of Code 93 0009 Code length that must match for Code 93 C CODE93 sample length 8 plus Suffix Symbol ID 1 9 43 Start character match...

Page 71: ...ne extremely high Frequency 2 93 kHz Power on beep No power on beep 0 1 2 3 4 5 6 Power On Indicator SS SS SS Disable LED off LED steady on LED flash F560 series scanner doesn t support this function...

Page 72: ...n Control A Series Buzzer Volume F_DEFAULT Family Code Selection P C Parameter Selection Option Code Buzzer Volume SS SS SS Low Medium High 0 1 2 Buzzer Volume Available firmware A680 A780 1 00 01 and...

Page 73: ...T Family Code Selection P C Parameter Selection Option Code Redundancy SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading 0 1 2 3 4 5 1D Barcode Inverse R...

Page 74: ...t time out Medium time out Long time out Force verification 0 1 2 3 4 5 Good Read Delay SS SS SS SS SS SS SS None 200 msec 500 msec 1 sec 1 5 sec 2 sec 3 sec 0 1 2 3 4 5 6 The Reread Delay Double Scan...

Page 75: ...source time out counter for Alternative Mode Presentation Mode and Level Mode The scanner keeps the light source on till the pre defined light source on time is up You can adjust this parameter to me...

Page 76: ...e 0 1 Presentation Sensitivity SS SS SS SS SS SS SS Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 0 1 2 3 4 5 6 When enabling the Presentation Auto sense the scanner can be switched from han...

Page 77: ...0 1 2 3 4 5 6 DataWizard is the most powerful Artificial Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers Through DataWizard you can process t...

Page 78: ...FIN 4th Insertion SS DS Disable Enable 2 digits identified position max 3 insertion characters FIN 2 digits position 1 3 characters FIN The Data Formatter is used to edit the scanned raw data prior t...

Page 79: ...cter SS DS Disable Enable 2 digits checking position 1 identified character FIN 2 digits position 00 7F The Data Verifier is used to provide advanced verification for error free scanning and to work a...

Page 80: ...osition 1 replacement character FIN 2 digits position 00 7F The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to se...

Page 81: ...data excluded the data of identified position Transmitted data included the data of identified position 0 1 The Data Organizer is used to edit the scanned raw data prior to transmitting the data to t...

Page 82: ...EAN 13 with 5 supplement 44 GS1 DataBar 14 EAN 8 05 GS1 DataBar Limited 22 EAN 8 with 2 supplement 35 GS1 DataBar Expanded 23 EAN 8 with 5 supplement 45 Composite Codes 24 Codabar NW 7 06 IATA 15 Cod...

Page 83: ...7 6 Actual Output A81025 TAB SN123456 TAB 76 TAB Programming Procedure Data Verifier Scan Program to enter the programming mode Scan Verifier Control and set bar code symbology to 48 Interleaved 2 of...

Page 84: ...anization and set the identified position to 16 then set the data transmission to 0 forward Scan 2nd Organization and set the identified position to 17 then set the data transmission to 1 backward Sca...

Page 85: ...45 is transmitted as E449123562 E212345 Code 128 Code 128 01 B C m Code 93 Code 93 09 H G m GS1 128 31 C 1 Code 11 Code 11 10 P H m Codabar Codabar NW 7 06 D F m MSI Plessey MSI Plessey 11 R M m Code...

Page 86: ...de A0 b Q m British Post British Post B1 h X 0 Micro QR Code Micro QR Code Intelligent Mail barcode Intelligent Mail barcode B3 j 0 Data Matrix Data Matrix A1 c d m Japanese Post Japanese Post B4 k 0...

Page 87: ...rl Z 11 VT 0BH F3 Ctrl K 27 ESC 1BH PAGE DOWN Edit Ctrl 12 FF 0CH F4 Ctrl L 28 FS 1CH UP Edit Ctrl 13 CR 0DH ENTER CR Ctrl M 29 GS 1DH DOWN Edit Ctrl 14 SO 0EH F5 Ctrl N 30 RS 1EH LEFT Edit Ctrl 6 15...

Page 88: ...family Refer to the Hex ASCII Table you will find the HEX value of is 24 Scan the option code 2 listed on the fold out back cover Scan the option code 4 listed on the fold out back cover Scan the sys...

Page 89: ...ng Manual Appendix 83 Host Interface Quick Set RS232 Serial PS 2 DOS V KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS 2 DOS V KBW Turbo Mode USB HID Turbo Mode USB HID Legacy Mode USB...

Page 90: ...e Quick Set F L Series Low Power Low power trigger Force Continued power on Alternative Periodic power off Trigger External triggering Toggle Repeat reading Flash Pulse driven reading Presentation Aut...

Page 91: ...ion Mode Quick Set A Series Low Power Low power trigger Force Continued power on Alternative Periodic power off Trigger External triggering Toggle Repeat reading Level Auto power off Presentation Auto...

Page 92: ...FuzzyScan Programming Manual Appendix 86 Option Codes 0 A 5 F 1 B 6 2 C 7 3 D 8 4 E 9 FIN Finish Abort END Exit...

Page 93: ...r Default After scanning Master Default command the scanner will remain the pre set parameters of Host Interface Selection Keyboard Interface Control except Record Suffix Preamble Postamble Serial Int...

Page 94: ...FuzzyScan Programming Manual Appendix 88...

Reviews: