9
1. MATERIALS
Select the correct type of materials below, based on the
type of installation shown above.
•
Pipe bend for outlet air
•
Wall bracket for outlet air pipe
•
Roof feedthrough for passing through external roof.
The type of feedthrough required will depend on the
type of roof covering material.
•
Ventilator for inlet air, min. Ø 160 mm / 201 cm2.
2. TOOLS
•
Drill
•
111 mm dia hole saw for cutting holes for outlet
and inlet air pipes.
•
168mm dia. hole saw for the inlet air ventilator.
•
Long drill bit for a pilot hole through wall.
•
Saw
•
Folding rule
•
Marker pen
•
Rasp and/or file
Alternative B
The outlet air pipe is fed through the wall and above
the roof. Inlet air is supplied through a 160mm ventila-
tor in the external wall.
Examples of installation
Cinderella Classic may be installed in a number of different ways.
The most important thing is to ensure a good flow of inlet and outlet air.
Two alternatives are shown below as a point of departure for this installation manual:
Inlet air
Inlet air
Alternative A
The outlet air pipe is fed through the wall and above the
roof. Inlet air is supplied through a 160mm ventilator in
the external wall.