5.2 Digital I/O (DIO) Hardware Specification
• XCOM+ / 2XCOM+ : Isolated power in V+
• XCOM- / 2XCOM- : Isolated power in V-
• Isolated power in DC voltage :
9~30V
• 8x / 16x Digital Input (Source Type)
• Input Signal Voltage Level
- Signal Logic 0 : XCOM+ =
9V
,
Signal Low
-
V-
<
1V
XCOM+ >
9V
,
V+
-
Signal Low
>
8V
- Signal Logic 1 : >
XCOM+
-
3V
• Input Driving Sink Current :
- Minimal : 1 mA
- Normal : 5 mA
• 8x / 16x Digital Output (Open Drain)
- DO Signal have to pull up resistor to XCOM+ for external device, the
resistance will affect the pull up current
- Signal High Level : Pull up resistor to XCOM+
- Signal Low Level : = XCOM-
- Sink Current: 1A (Max)