DS-1200 Series Rugged Embedded Computer
| User’s Manual
CN-TB-QP22-44_V1.0
82
❑
Serial Port [Enabled]
Enables or disables serial port.
❑
Change Settings [Auto]
Allows you to change the IO Address & IRQ settings of the specified serial port.
❑
Onboard Serial Port 1~6 Mode [RS232]
Allows you to select Serial Port Mode.
Configuration options: [RS232] [RS422/RS485 Full Duplex] [RS485 Half Duplex]
Watch Dog Function
You can setup the system watch-dog timer, a hardware timer that generates a reset
when the software that it monitors does not respond as expected each time the
watch dog polls it.
■
Watch Dog [Disabled]
Enables or disables watch dog function.
■
Watch Dog Mode [Sec]
Allows to set watchdog timer unit <Sec> or <Min>.
■
Watch Dog Timer [0]
Allows you to set watchdog timer’s value in the range of 0 to 255.
Summary of Contents for DS-1200 Series
Page 12: ...Product Introductions Chapter 1 ...
Page 20: ...DS 1200 Series Rugged Embedded Computer User s Manual CN TB QP22 44_V1 0 20 DS 1202 Unit mm ...
Page 21: ...Pin Definitions and Settings Chapter 2 ...
Page 23: ...DS 1200 Series Rugged Embedded Computer User s Manual CN TB QP22 44_V1 0 23 2 1 2 Bottom View ...
Page 34: ...System Setup Chapter 3 ...
Page 72: ...BIOS Setup Chapter 4 ...
Page 98: ...Product Application For DIO only Chapter 5 ...
Page 101: ...DS 1200 Series Rugged Embedded Computer User s Manual CN TB QP22 44_V1 0 101 ...
Page 102: ...DS 1200 Series Rugged Embedded Computer User s Manual CN TB QP22 44_V1 0 102 ...
Page 103: ...DS 1200 Series Rugged Embedded Computer User s Manual CN TB QP22 44_V1 0 103 ...
Page 115: ...Optional Module Pin Definitions and Settings Chapter 6 ...