Steam Injector and Plate Coil
PROBLEM
DIAGNOSIS
Low steam pressure.
Will not heat.
Clogged injector.
Clogged strainer.
Back pressure in condensate line. (Plate coil only.)
Faulty steam trap.
Overheats.
Temperature controller improperly adjusted.
Faulty temperature controller.
PROBLEM
DIAGNOSIS
Will not light.
Gas turned off.
Faulty temperature controller.
Faulty thermocouple.
Faulty igniter, igniter module, or plug. (See Burner manual for more.)
Faulty low level float switch.
Shuts off periodically.
Loss of gas (Low/High Pressure).
Improper adjustment of complete unit.
Negative air pressure.
Fire will not enter tube.
Negative air pressure—draft inducer required.
Overheats.
Temperature controller set too high.
Faulty temperature controller.
Low gas pressure.
Does not heat.
Temperature set too low.
Mixture too lean.
Mixture too rich.
Faulty temperature controller.
Gas Burner
Control Panel
A qualified electrician should be called in for trouble
-
shooting and repair of the washer controls.
Page 17
KS-70 R
ACK
W
ASHER
T
ROUBLESHOOTING
G
UIDE