![CIMLINE MA4 Owner'S/Operator'S Manual Download Page 13](http://html.mh-extra.com/html/cimline/ma4/ma4_owners-operators-manual_2607224013.webp)
13
1)
MAIN CONTROL SWITCH
:
Auto:
(left position) Machine will operate from the systems preconfigured program using the
rotary switch control located on the outside front cover.
Off:
(center position) Power to all systems will be off and burner, pump and agitator will stop.
Manual
: (right position) Main rotary switch on front cover is no longer active. The three
switches below for temperature control, pump and agitator must be used to control the melter’s
operations.
2)
TEMPERATURE CONTROLLER ON / OFF SWITCH:
When this switch is on, the three digital
controllers to the right will be energized and they will be controlling the diesel burner and activate the
hydraulics for agitator motor and sealant material pump.
3)
MATERIAL PUMP:
Seal (Forward):
When this switch is on “ Seal (Forward)” the pump will be rotating with sealant
material recirculating back to sealant material tank. When key fob remote switch is activated, sealant
material will dispense out of the spray tips on the application bar.
Off:
When the switch is “ Off” , the pump will not be rotating.
Clean-out (Reverse) Switch:
When the switch is on “ Clean-out”, the pump will be rotating in the
reverse direction and will be drawing back any sealant material in the plumbing or the application bar
system back to the sealant material tank.
4)
AGITATOR CCW / OFF / CW SWITCH:
This switch controls the rotation of the agitator from counter-
clockwise (CCW) or clockwise (CW). If the switch is in the center position, the agitator will not rotate.
5)
SEALANT TEMPERATURE CONTROLLER:
The control system on your CIMLINE melter has been
factory set to run the most common types of sealant materials. See page 19 to override or change
settings.
6)
MATERIAL READY LIGHT (Green):
This LED light indicates that the sealant material has
reached the preset temperature if the unit is running in the auto mode.
7)
HEAT TRANSFER OIL CONTROLLER:
The control system on you CIMLINE melter has been factory
set to not exceed the OEM heat transfer oil limits for maximum temperature. It is advised to only use
heat transfer oil from CIMLINE. See Page 22 for heat transfer oil information and specifications.
8)
AGITATOR READY LIGHT (Green):
This LED light indicates that the heat transfer oil has
reached the preset temperature and if the unit is running in the auto mode, the hydraulic circuit for the
agitator will be activated. If enough sealant material has melted the agitator should be turning.
9)
MATERIAL TANK TEMPERATURE CONTROLLER:
The control system on your CIMLINE melter
has been factory set to engage the sealant material pump early enough to get a faster start up. See
page 19 to override or change settings.
10)
PUMP READY LIGHT (Green):
This LED light indicates that the sealant material inside the
pump has reached the preset temperature and if the unit is running in the auto mode, the hydraulic
circuit for the sealant material pump will be activated. If enough sealant material has melted the pump
should be turning and sealant material should be circulating through the system and back into the top
of the sealant material tank.
11)
DIESEL BURNER LIGHT (Yellow):
This LED light indicates that the material and heat transfer
oil temperature control are demanding that the diesel burner circuit is turned on.
MA4 Manual Sub Control Panel and Its Functions
CIMLINE recommends using the Main Control Panel in “AUTO”
control mode. “MANUAL” mode is provided for trouble shooting
and trained advanced/experienced users.
NOTICE