20
Maintenance
Maintenance Operation
Daily
25 Hrs
100 Hrs
200 Hrs
500 Hrs/
Yearly
Check fuel level (add if low)
X
Check engine and heat transfer oil (add if low)
X
Check hydraulic oil (add if low)
X
Check engine air cleaner
X
Inspect pre-cleaner
X
Cleanout material system
X
Inspect sealing hose and cover
X
Inspect sealing hose connection
X
Inspect and clean cooling system
X
Inspect material pump packing
(adjust if leaking is excessive)
X
Service air cleaner element
X
Inspect material flow plumbing
X
Inspect burner nozzle, electrode & head pos.
(adjust if necessary)
X
Change engine oil and oil filter
X
Grease agitator bearing block (load adapter)
X
Inspect fuel filter (replace if dirty)
X
Inspect Diesel burner electric eye (clean if dirty)
X
Grease wheel bearings
X
Inspect chamber lining
(replace if excessive cracking)
X
Inspect starting motor
X
Replace hydraulic oil
X
Replace hydraulic return filter
X
Replace hydraulic suction strainer
X
Replace burner nozzle
X
Change heat transfer oil
X
Change Diesel fuel filter
X
Flush radiator and replace fluid
X
Summary of Contents for C1
Page 13: ...13 Sub Control Panel Controls and Their Functions 1 2 3 4 5 6 7 8 9 10 11 12 IMLINE ...
Page 31: ...31 Sealant Control Panel Wiring Diagram ...
Page 37: ...37 Tank Burner Internal Wiring Diagram ...
Page 39: ...39 Hydraulic Schematic For Compressor Hydraulics see Supplement manual ...
Page 45: ...45 Sealant Plumbing Components ...
Page 50: ...50 Mastic Mixer Assembly ...
Page 55: ...55 Miscellaneous Parts ...