- 33 -
Adjusting Burner Nozzle, Electrode and Head Position
Step 3: Setting Electrode Position
Insert gauge as shown below. The electrode tip should be in line with the intersection of the
cross hairs labeled "DC". If not, you must remove the head, then loosen the electrode retain-
ing screw just enough to allow you to slide the electrodes into the proper location. Tighten the
screws and replace the head.
Step 4: Setting Nozzle Position
Insert the gauge against the head. The end of the gauge should now touch the nozzle. If not,
slightly loosen the knurled nut and the screw on the escutcheon plate until the entire nozzle
assembly can be moved forward or backward. Adjust accordingly and tighten the knurled nut
and screw.
Electrode retaining screw
Escutcheon Plate
Knurled Locknut
Screw
DC