16
17
EN
EN
1. Slowly unlock the stopcock (6), thus
simultaneously and automatically stopping
the water (A1).
2. Lift the single lever to approx. 130° (B1) – Pull
out the supporting core, incl. filter cup and fil-
ter element (C1).
3. Dispose of the used filter element or
– for optimum hygiene – the complete hygienic
vault (environmentally-friendly plastic
recycling).
4. Insert the new filter element or hygienic vault
(A2), close the lever (B2). Slowly release the
stopcock/ unlocking device (6) (90° anti-clock-
wise) (C2).
5. Reset filter change display (LED) - Reset:
press LED button for 3 seconds, then 3
seconds of continual light as confirmation that
reset has been successful.
When reset is complete, the countdown runs
again from 6 months/182 days to 0.
6. To check the batteries of the filter change
display (LED) and functional query.
Briefly press the LED (< 3 secs.)
➔
5 x
rapid flashing, when the change display
is active and the countdown runs from
6 months/182 days to 0.
This function is simultaneously also a
battery check. If no flashing signal occurs, the
batteries must be replaced.
6. Commissioning
Check filter for proper ins-
tallation.
6.1 Set pressure reducer
(only Cillit C1 HWS)
The pressure reducer is un-
der the cap.
Simply remove the cap (2) to
reach the pressure reducer.
The pressure reducer is set to a back pressure of
4 bar at the factory. To change the back pressure,
loosen the locking screw (10) and turn the rotary
knob (11). The back pressure can be changed by
turning the setting knob (11) (control range 2 - 6
bar).
Clockwise rotation = higher back pressure.
Anti-clockwise = lower back pressure.
The manometer (5) displays the back pressure.
During setting, an outlet valve downstream from
the pressure reducer must be briefly opened and
closed again a number of times. When water is
removed, the back pressure is temporarily redu-
ced. The back pressure must not exceed 80 %
of the response pressure of the hot water safety
valve (DIN 1988-200).
6.2 Insert batteries in the filter change display
(7):
For impeccable, hygienic enjoyment of drinking
water in accordance with the standards, the filter-
element must be replaced at least every 6 months.
The installed LED display gives a timely warning
by means of a visual signal. The supplied batteries
must be inserted for commissioning:
- Remove the cap (2)
- Open the battery com-
partment cover using a
screwdriver
- Insert the batteries (2
x AAA): an automatic
function test occurs (5 x
slow flashing)
- Close battery compart-
ment and replace cover
The filter is now ready for
operation.
7. Operation
The filter and pressure regulation functions work
completely autonomously without the need for
operation. For impeccable, hygienic enjoyment of
drinking water in accordance with the standards,
it is only necessary to replace the filter element at
least every 6 months. The integrated LED display
gives a timely warning by means of a visual sig-
nal: the red LED flashes every 5 seconds.
- Flashing interval after 6 months/ 182 days
have elapsed: a red LED flashes every 5 se-
conds.
- Flashing period: after expiry of time until filter
change or reset occurs.
7.1 Replace filter and check batteries
With the new single lever operation, replacing the
filter element is easy and only takes seconds:
B1
A1
C1
C2
A2
B2