EREBA ACCESS 17 - 40 T/HT
EN - 2
1 - PHYSICAL DATA AND ELECTRICAL DATA - MODEL T
Table I: Physical data - Model T
Table II: Electrical data - Model T
EREBA
017 021
026
033
040
Operating weight
with hydraulic module Kg
189
208 255 280 291
Refrigerant charge R-410A Kg
5.5
6.4 5.8 8.6 8.8
teqCO
2
11.5 13.4
12.1
18
18.4
Compressor
One scroll compressor
Evaporator
One plate heat exchanger
Net water volume l
1.52
1.9
1.71
2.28
3.8
Water connections (MPT gas) inches
1
1
1-1/4
1-1/4
1-1/4
Maximum water pressure kPa
400
400
400
400
400
Hydraulic module
Pump, mesh filter, expansion tank, flow switch, automatic air purge valve and drain plug
and relief valve.
Pump
One single-speed pump
Water inlet connection (MPT gas) inches
1-1/4
1-1/4 1-1/4 1-1/4 1-1/4
Water outlet connection (MPT gas) inches 1
1
1-1/4
1-1/4
1-1/4
Closed expansion tank water volume l
5
5
8
8
8
Pre-charge of expansion vessel bar
1.5
1.5 1.5 1.5 1.5
Condenser
One, copper tubes and aluminium fins
Fan
Two,axial type with two speeds
Two-speed axial type
Diameter mm
495
495
710
710
710
No. of blades
3
3
7
7
7
Air flow (high speed) l/s
2212
2212
3530
3530
3530
Fan speed (high speed) g/min
870
870
900
900
900
Sound levels
Sound power level 10
-12
W* dB(A)
72
74
78
78
80
* Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +3dB). The values have been rounded and
are for information only and not contractually binding.
EREBA
ACCESS
T
017
021 026 033 040
Power
V-ph-Hz
400-3+N-50 (power supply option C) or 400-3-50 (power supply option D)
400-3-50
(STD - no option)
Voltage
range
V
340-460
360-440
Starting current*
A
75
95
118
118
176
Maximum power drawn (Vn) **
kW
7.8
9.1
11.0
13.8
17.5
Nominal current drawn***
A
8
12
16
17
25
Maximum current (Vn) ****
A
13
16
20
24
30
Maximum current (Vn +/-15 or 10%) †
A
15
18
23
27
36
* Max. starting current within the operation limits (corresponding to the current of locked rotor in the compressor)
** Input power when the unit is at its operation limits (evaporation temperature = 10°C, condensation temperature = 65°C) and at the rated voltage (400 V)
*** The currents shown refer to Eurovent conditions (evaporator water inlet and outlet temperature = 12/7°C with air to the condenser at 35°C)
**** Max. operating current related to the max. input power and rated voltage (400 V)
† Max. operating current related to the max. input power and within the range 340-460 V for units size 17 to 33 kW, and 360-440 V for units size 40 kW.
Summary of Contents for EREBA ACCESS 17-40 T/HT
Page 1: ...EREBA ACCESS 17 40 T HT 11 2017 X0178 Instruction manual...
Page 2: ......
Page 113: ...RU RU 111 NR 17 19 A 5 70 o C R 410A CIAT 0 C 300 2...
Page 114: ...NR 17 19 A RU 112 10 15 CIAT 7511632 17 21 7511634 26 40 16 26 40 I 26 40 1 2 15...
Page 121: ...RU RU 119 NR 17 19 A 26 40 6 9...
Page 126: ...NR 17 19 A RU 124 II II 5 5 1 5 100 C 15 C RTPF AFNOR X60 010 12...
Page 127: ...RU RU 125 NR 17 19 A 1 2 X X X X X X 1 EN 378 3 2 1 EN 378 1 CIAT CIAT EN 378 4 1 1 EN 378...
Page 128: ...NR 17 19 A RU 126 EREBA ACCESS HT 4 13...
Page 129: ......