CIAS Elettronica S.r.l.
Ed. 2.2
Installation Handbook
page
37
to
43
ERMO 482
4. ADJUSTMENT AND TESTING
4.1 Adjustment and Testing with STC 95 Instrument
For the Microwave Barrier Adjustment and Testing, CIAS gives the availability of a dedicated
instrument, with the intention to facilitate installation operation and operator activity support.
The following figure 10 shows the CIAS STC 95 instrument with function explanations.
Figure 10
1
3M connector
13
Increasing threshold Buzzer activation key.
2
LCD Display
14
Decreasing threshold Buzzer activation
key.
3
LED strip
15
Buzzer activation / deactivation key.
4
Power supply LED test 13,8 V
16
Buzzer activation LED
5
Received field LED test
17
Open / closed Loop key
6
Check Sens.RX / RF TX LED
18
Open loop LED indication
7
AGC LED check
19
Activation / deactivation tests key TX / RX 2
and Medusa
8
Power supply LED test TX 9 V
20
Test indication LED RX / TX 2
9
Power supply LED test RX 5 V
21
Measurement activation / deactivation key
TX / RX 1, MEDUSA, ERMO, ERMUSA,
MINERMO
10
Tests selection key
22
Test indication LED TX / RX 1, MEDUSA,
ERMO, ERMUSA, MINERMO
11
Manual increasing gain key
23
RCA for scope connection with supplied
cable
12
Manual decreasing gain key
Summary of Contents for ERMO 482
Page 47: ...NOTE...