Usage
Remove the battery activation strip to activate batteries. It will
enter working mode after one-minute's self-testing.
I Mode Setting I
Testing mode:
Press test button, the sensor enters testing mode
and detects once every 10 seconds. After 3 minutes, the LED
flashes twice, the sensor enters the working mode.
Working mode:
In working state, if the sensor is triggered twice
within 3 minutes, it will enter sleeping mode to save power.
After no movement within next 3 minutes, the sensor goes back
to the working mode.
Installation & Notice
Choose a suitable position and fix the mounting plate on the
ceiling with screws. Fasten the detector on the mounting plate in
a clockwise direction. It is suggested to mount it at the height of
2.5-5 meters from the ground.
Keep the detector away from air conditioner, electronic fan,
refrigerator,
oven,
heater or any other objects which will cause
fast temperature changing.
Avoid mounting it in direct sunlight or any objects blocking the
lens, so as not to influence the detection effect.
0
0
(i
0
Testing (Walk Test)
After installation, power on the detector. After self-testing for 1
minute, press the test button, walk in the scope by crossing the
infrared spectrum (see below diagram), and watch the LED
indicator to make sure it is working. The LED indicator will flash
once when body movement is detected.
High detection sensitivity
Low detection sensitivity
I Connect with the Control Panel
When the control panel is in connecting state, press the test
button twice to send wireless signal. One beep is heard after
panel receives signal, which means successful connection.
Arm the system, trigger the detector again. The panel will alarm
immediately. This indicates the detector has successfully
connected with the panel.
Specifications
Power Supply:
DC 3V (AA LR6 1.5V Battery x 2pcs)
Static Current:
� 50uA
Alarm Current:
� 9.5mA
Installation Height:
2.5-6m
Detection Scope:
Dia. 6m (when installation height is 3.6m)
Transmitting Distance:
� 80m (in open area)
Radio Frequency:
315MHz or 433MHz (± 75KHz)
Housing Material:
ABS Plastic
Operation Condition
Temperature: -l0
°
C ~ +50
°
(
Relative Humidity:� 80%RH (non-condensing)
Detector Dimensions (L x W x H):
90 x 90 x 36.8mm
Mounting Plate Dimensions (L x W x H):
56
x
56 x 8mm
Ver: 700-EN-1307-2.0