background image

23

24

Restoring to Factory Settings

 

Press the Network Configuration button underneath the hub for 10 seconds, 

hearing one beep at the third second then a long beep at the tenth second, 

which indicate the operation is complete. Release the button and the hub will 

automatically restart afterwards.

Note: 

Previously paired accessories will remain connected to your hub after a restore.

Specifications

Hub

Power Supply

5-12Vdc 6W

Battery

1.5V AA LR06 battery x 4

WiFi

IEEE 802.11b/g/n

Standby Current

< 56mA

Alarm Current

< 208mA

Internal Siren 

90dB/1m

Optional Accessories 

10 Remote Controls, 50 Sensors

Radio Frequency 

433.92 MHz or 315 MHz

*Only 433.92MHz is available for Europe

EIRP(dBm).Max 

13.99

ERP(dBm).Max 

-16.45

Receiver Category 

Category 2 (standard performance level of 

receiver)

Housing Material 

ABS Plastic

Operating Condition 

Temperature 0°C~50°C,

Relative Humidity <80% (non-condensing)

Control Panel Dimensions 

125 x 150 x 30 mm (L x W x H)

Bracket Dimensions 

87.5 x 81.5 x 12 mm (L x W x H)

Remote Control

Power Supply 

DC 3V (CR2025 lithium battery x 1pc)

Transmit Current 

<8 mA

Transmitting Distance 

<80 m (open area/no interference)

ERP(dBm).Max 

-14.81

Radio Frequency 

433.92 MHz or 315 MHz

*Only 433.92MHz is available for Europe

Housing Material 

ABS Plastic

Operating Condition

Temperature 0°C~50°C,

Relative Humidity <80% (non-condensing)

Dimensions

58 x 31 x 9.5 mm (L x W x H)

Door/ Window Contact 

Power Supply 

DC 3V(Lithium battery x 2pcs)

Static Current 

<56 uA

Alarm Current 

<82 mA

Transmitting Distance 

<80 m (open area/no interference)

ERP(dBm).Max 

-12.06

Radio Frequency 

433.92 MHz or 315 MHz

*Only 433.92MHz is available for Europe

Housing Material 

ABS Plastic

Operating Condition 

Temperature 0°C~50°C,

Relative Humidity <80% (non-condensing)

Transmitter Dimensions 

71 x 34 x 17.5 mm (L x W x H)

Magnet Dimensions 

51 x 12 x 13.5 mm (L x W x H)

Summary of Contents for OV-300

Page 1: ...OV 300 WiFi Alarm System User Manual...

Page 2: ...the products as shown in this document is subject to change without notice The reproduction language translation modification storage in a retrieval system or re transmission in any form or by any mea...

Page 3: ...a push notification will automatically be sent to you and other pre authorized users The system can be controlled and monitored both on site using the remote control supplied and remotely with the Dr...

Page 4: ...sarm Arm Away Mode Home Arm Part Arm SOS Button Arm Away Mode Status Indicator Disarm SOS Button Home Arm Part Arm Button System Status Sets the system to Arm Away mode Set to this mode when the prope...

Page 5: ...s once Tamper Switch The tamper switch small black button underneath the back cover will activate the alarm if an unauthorized attempt is made to remove the contact from its installed location Low Bat...

Page 6: ...Confirm to enter the Wi Fi password for the connected network Then connect to OV 300 Alarm on the Wi Fi list from your mobile device Once connected return to the app and wait for the connecting proces...

Page 7: ...for anomalies during this mode The hub internal siren will sound immediately when a sensor is triggered You and other pre authorized users will receive push notifications on your phones This mode is...

Page 8: ...of the house Home Zone Sensors set to Home Zone are only activated when the system is in Away Full Arm status During Home Arm mode these sensors can not activate the alarm on triggered We recommend s...

Page 9: ...When connecting an Outdoor Siren optional accessory to the Hub you can enable the arm disarm alert sound of the siren on the app Timed Arm Disarm The system can be programmed to automatically Arm and...

Page 10: ...ithout triggering an alarm You can choose to switch on the delay alert sound Test Mode Under test mode if you trigger any sensors the system will not sound the alarm but give out 3 beeps You can quit...

Page 11: ...sword and delete your account Home Management You can check all your created home s and the home s that shared with you by other accounts Tap Me on the main page and tap Home Management to add home na...

Page 12: ...re sharing the device s to other users or changing the settings are not permitted Message Center Alerts Here you can check hub s arm disarm and triggered events Bulletins Here you can check all syste...

Page 13: ...d to ensure the best possible connectivity Door Window Contact Step 1 To power up the contact remove the battery tab Step 2 Attach the adhesive pads to the back of the transmitter and magnet Step 3 Pl...

Page 14: ...ating Condition Temperature 0 C 50 C Relative Humidity 80 non condensing Control Panel Dimensions 125 x 150 x 30 mm L x W x H Bracket Dimensions 87 5 x 81 5 x 12 mm L x W x H Remote Control Power Supp...