background image

 

 

 

 
 
 
 

 

NOTE:  BEFORE INSTALLATION, COMPARE ELECTRICAL 
NEEDED FOR THE MODEL OF HEATER SELECTED.

INSTANT-FLOW   MICRO SPECIFICATIONS:
DIMENSIONS:

6-1/4” [159 mm] X 9-5/8” [244 mm]  X 2-3/4” [70 mm] 

WEIGHT:

5 LBS. [2.27 Kg] 

MATERIALS:

ALUMINUM HOUSING, CELCON WATERWAYS, NICHROME PARTS 

COLOR:

WHITE

PIPE FITTINGS:

3/8” COMPRESSION

OPERATING PRESSURE RATING:

25 PSI [172 kPa] MINIMUM, 80 PSI [551.6 kPa] MAXIMUM 

MAXIMUM PRESSURE RATING:

 

150 PSI [1034.2 kPa] NO PRESSURE RELIEF VALVE NEEDED 
UNLESS REQUIRED BY LOCAL CODES.

MAXIMUM OPERATING TEMP:

160°F [71°C] 

MINIMUM OPERATING FLOW RATE:

0.35 GPM [1.3 LPM]

LISTINGS:

UL, HUD, IAPMO, UPC, ETL 

FACTORY SET TEMPERATURES:

104°F [40°C]
110°F [43.3°C]
120°F [48.9°C]
Other temperature settings are available upon request up to160°F [71°C]. Temperature settings are not field adjustable. 110°F 
[43.3°C] / 120°F [48.9°C] settings are recommended with cold water mixing faucets.

®

HOW INSTANT-FLOW  MICRO WORKS

The engineered plastic case houses a series of ingeniously designed coils that instantly heat water as it flows through the vessel. A 
unique power switch automatically applies electrical current to the coils when hot water is requested. The electrical current is not applied 
when the water is not in use. The microprocessor is internally preset at the factory to maintain a constant output temperature with 
varying flow rates.

CHRONOMITE TECHNICAL SUPPORT

TOLL FREE

 800-447-4962 • 

LOCAL

  626-937-4270 • 

FAX

 626-937-4279

3100-003-001
II-927 06/17 REV 9

Page 2 of 8

MODEL

VOLTAGE

ACTIVATION

.80 GPM [3.0 LPM]

1.0 GPM [3.8 LPM]

1.2 GPM [4.5 LPM]

M-15L

277

0.35 GPM [1.3 LPM]

35°F [20°C]

28°F [16°C]

24°F [13°C]

M-20L

120

0.35 GPM [1.3 LPM]

20°F [11°C]

-

-

M-20L

208

0.35 GPM [1.3 LPM]

36°F [20°C]

28°F [16°C]

24°F [13°C]

M-20L

240

0.35 GPM [1.3 LPM]

41°F [23°C]

33°F [18°C]

27°F [15°C]

M-20L

277

0.35 GPM [1.3 LPM]

47°F [26°C]

38°F [21°C]

32°F [18°C]

M-30L

120

0.35 GPM [1.3 LPM]

31°F [17°C]

25°F [14°C]

20°F [11°C]

M-30L

208

0.35 GPM [1.3 LPM]

53°F [30°C]

43°F [24°C]

36°F [20°C]

M-30L

240

0.35 GPM [1.3 LPM]

61°F [34°C]

49°F [27°C]

41°F [23°C]

M-30L

277

0.35 GPM [1.3 LPM]

71°F [39°C]

57°F [32°C]

47°F [26°C]

M-40L

208

0.35 GPM [1.3 LPM]

71°F [39°C]

57°F [32°C]

47°F [26°C]

M-40L

240

0.35 GPM [1.3 LPM]

82°F [46°C]

66°F [36°C]

55°F [30°C]

INCOMING WATER TEMPURATURE INCREASE

®

INSTANT-FLOW  MICRO
SPECIFICATIONS

(LOW ACTIVATION MODELS)

!

IMPORTANT

Before installation of heater, review electrical 
requirements needed for model of heater 
selected.

MICROPROCSSOR LIMITS TEMPERATURE INCREASE ACCORDING TO FACTORY SET TEMPERATURE.

MODEL WATTAGE VOLTAGE

AMPS

MODEL WATTAGE VOLTAGE

AMPS

INTERMITTENT 

DUTY

CONTINUOUS 

DUTY

INTERMITTENT 

DUTY

CONTINUOUS 

DUTY

M-15L

4150

277

15

15

20

M-30L

6240

208

30

30

40

M-20L

2400

120

20

20

30

M-30L

7200

240

30

30

40

M-20L

4160

208

20

20

30

M-30L

8320

277

30

30

40

M-20L

4800

240

20

20

30

M-40L

8320

208

40

40

50

M-20L

5540

277

20

20

30

M-40L

9600

240

40

40

50

M-30L

3600

120

30

30

40

BREAKER SIZE

BREAKER SIZE

TABLE 1

®

Chronomite Laboratories is a Member of Morris Group International™

ELECTRIC TANKLESS WATER HEATER - POINT OF USE

Summary of Contents for M-15L

Page 1: ...com TABLE OF CONTENTS 2 Dimensional Data 3 Installation 4 5 Specifications 6 Troubleshooting 7 Warranty Information 8 Technical Information REQUIRED ITEMS FOR INSTALLATION NOT SUPPLIED Electrical Junc...

Page 2: ...937 4270 FAX 626 937 4279 3100 003 001 II 927 06 17 REV 9 Page 2 of 8 MODEL VOLTAGE ACTIVATION 80 GPM 3 0 LPM 1 0 GPM 3 8 LPM 1 2 GPM 4 5 LPM M 15L 277 0 35 GPM 1 3 LPM 35 F 20 C 28 F 16 C 24 F 13 C M...

Page 3: ...8 INSTANT FLOW MICRO DIMENSIONAL DATA 3100 003 001 II 927 06 17 REV 9 101 8 257 1 1 16 27 17 8 48 1 1 16 27 23 4 70 1 1 16 27 53 4 146 1 4 6 1 4 6 95 8 244 7 32 6 3 5 16 84 2 51 61 4 159 Chronomite L...

Page 4: ...ly open Do not throttle inlet 5 Turn on circuit breaker Turn on water flow to exceed activation point listed in chart 2 The unit is almost ready for use Shut off circuit breaker 6 Check for leaks at a...

Page 5: ...to follow these installation and operation instructions NOTICE Air in the heater may cause the elements to burn out If the water lines are drained allowing air into the heater be sure to follow the fo...

Page 6: ...exceed GPM LPM however less water can always be used Consumer can mix the cold water as with a conventional system See Flow Control Models Chart below CHRONOMITE TECHNICAL SUPPORT TOLL FREE 800 447 4...

Page 7: ...fer to Figure x for location This reading should be between 6 and 30 ohms for each element 8 Check Flow Rate Controlling flow rate is essential to insure proper temperature increase In the case of the...

Page 8: ...local plumbing and or building codes and or regulations 2 Chronomite is not liable under this warranty if the water heater has not been continuously supplied with potable water or the water inlet tem...

Reviews: