OPERATION INSTRUCTIONS:
Ÿ
Turn the hot water fixture to activate the flow switch. The flow switch activates at 0.35 gallons per minute (GPM) [1.3 LPM] and
deactivates at 0.30 gallons per minute (GPM) [1.1 LPM].
Ÿ
If you increase the flow rate of the water above the KW capacity, the water temperature will become cooler. Cold water can always be
mixed just as with a conventional system if using a two handle faucet. Select the appropriate flow control.
Ÿ
Once you decrease the hot water flow rate to 0.30 GPM [1.3 LPM] the unit will deactivate. It is not advisable to operate the heater
at 0.30 GPM [1.3 LPM] hot water flow rate.
NOTES:
1. Periodically inspect (4 times a year) the supply lines, connections and heater for any moisture, corrosion or other potential
preventable problems.
2. Prior to shutting off water valves for servicing, winterization, etc, always disconnect power from unit 1st.
3. Unit is intended to heat water only, and does not provide a means of cooling if inlet temperature exceeds set point temperature of
heater.
OPTIONS:
• PA 765 ABS Housing (P)
• Pressure & Temp. Relief Valve Assembly (TP)
• Satin Finish Stainless Steel Housing (SS)
• 1/2” Male NPT (NPT08)
• High Polish Finish Stainless Steel (SSP)
• Disconnect Switch, Rotary 40A - Lockable Nema 4X (2095-1)
FLOW CONTROLS:
You may want to install the supplied flow control in your design. This high-quality control makes the water heating system operate more
effectively, as well as save water. the supplied GPM [LPM] flow control assures that the flow rate will not exceed GPM [LPM], however, less
water can always be used. Consumer can mix the cold water as with a conventional system. See Flow Control Models Chart below.
CHRONOMITE TECHNICAL SUPPORT
TOLL FREE
800-447-4962 •
LOCAL
626-937-4270 •
FAX
626-937-4279
Page 6 of 8
®
INSTANT-FLOW MICRO SPECIFICATIONS
(LOW ACTIVATION MODELS)
3100-003-001
II-927 06/17 REV 9
KW
ACCESSORY
PACKAGE
45 psi
45 psi
1.8 - 3.6
AP-1-P
L412-0.5-NP
0.5 GPM SPRAY
L412-1.0-NP
1.0 GPM SPRAY
4.0 - 5.0
AP-2-P
A412-1.0-NP
1.0 GPM LAMINAR
A412-1.5-NP
1.5 GPM LAMINAR
6.0 - 12.0
AP-3-P
A412-2.0-NP
2.0 GPM LAMINAR
-
FLOW CONTROL MODELS CHART
!
NOTICE
•
Flow controls are adaptable to other
thread configurations. Please call
factory if adapter is needed.
!
IMPORTANT
Periodically inspect (4 times a year) the supply
lines, connections and heater for any moisture,
corrosion or other potential preventable problems.
104°F
***110°F
***120°F
Notes:
*
**
***
FACTORY SET TEMPERATURES
Other Temperature Settings are available upon
request up to 140°F
Temperature Settings are not Field Adjustable
110°F / 120°F Temperature Settings are not
recommended w ith metering / sensor faucets
(cold w ater mix needed)
<
≥
LOW FLOW RATE SYSTEM:
For applications where 0.20 - 0.35 GPM (0.75 - 1.3 LPM) Flow Rate is
desirable, see our CM series heaters.
FLOW CONTROL SPECIFICATIONS
MATERIAL:
Chrome plated, brass housing.
THREADING:
DUAL threads 15/16” male
55/64” female
NOTE:
Flow controls are adaptable to other thread configurations.
Vandal resistant models are available. Please call factory
If adapter or vandal resistant model is needed.
Chronomite Laboratories is a Member of Morris Group International™
ELECTRIC TANKLESS WATER HEATER - POINT OF USE
FIGURE 2
FLOW CONTROL
INSTALLATION
(See Parts List #8)