TROUBLESHOOTING GUIDE

Your Instant-Flow Micro water heater has no internal user serviceable parts and should be returned to the factory for repair or 
replacement. Please contact factory for return authorization. If after following the Installation Instructions, your Instant-Flow 
MICRO does not heat water in accordance with this literature, please check the following:

1.

Low Power

 – Verify your voltage by using a voltage meter. You should obtain your reading off the two outside terminals 

located on the heater. Compare the reading against the voltage specified in the Installation Instructions. The center 
terminal is always the earth ground. The hot and neutral legs, in the case of 110 V heaters, are attached on the two 
outside terminals.   

2.

Low Voltage

 – The percentage of reduction in voltage will result in a like reduction in temperature increase.     

3.

Check Low Amperage Draw 

– Check amperage draw using an Amperage Probe.  Please compare your results with 

the Installation Instructions (Table 1) to determine if the heater is operating correctly.    

4.

Length of Pipe

 - Length of pipe run will affect the temperature increase.  The heater should be mounted no more than 

12-18 inches [ 305mm-457mm] from the point of use.   

5.

Check shut off valve.

 Check shut-off valve and make sure valve is open 100% to allow full water pressure and flow to 

the heater.   

  

6.

High-Limit Thermostat -

 Shut off power on breaker.  Remove cover.  Push in reset button on module.  Refer to Figure 

2 for location.  Reinstall cover.  Turn on breaker.  If problem persists, contact factory. 

7.

Heater Element -

 Shut off power on circuit breaker.  Remove cover.  Measure element resistance by using an 

ohmmeter or multi-meter. Obtain your reading off of termination rods with brass nuts on each heater module.  Refer to 
Figure x for location.  This reading should be between 6 and 30 ohms for each element.  

8.

Check Flow Rate

 – Controlling flow rate is essential to insure proper temperature increase. In the case of the low flow 

rate heater it is mandatory that the flow control be attached to the end of the faucet. Check your flow rate to insure 
proper operation of the heater. Low Flow Rate Models require 0.35 GPM (1.3 LPM) to activate. 

9.

Installation

 – Heater must be installed in a horizontal position. The silver label will then be located in the upper left 

corner as you face the heater. 

10.

Water Supply

 – Do not throttle water supply to inlet of Instant-Flow MICRO. Operating conditions shall not exceed 

specification on page 2. 

11.

Freezing

 – Instant-Flow MICRO heaters must be drained and stored if installed in a location subject to freezing. 

Disconnect the inlet/outlet compression fittings and blow air through one side of the heater to assist draining. Failure to 
completely remove water from the unit will result in freezing and cracking. 

12.

Problems?

- Call our toll-free hotline 800-447-4962 or 626-937-4270  

WARNING

-  This water heater is not intended for use by persons (including children) with reduced physical, sensory or
    mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
    instruction concerning use of the water heater by a person responsible for their safety. 
-  Children should be supervised to ensure that they do not play with the water heater.
-  The water resistivity must not be less than 1100 OHM-CM.
-  The water heater must be earth grounded.
-  The water heater is not to be installed in locations where freezing can occur.

CHRONOMITE TECHNICAL SUPPORT

TOLL FREE

 800-447-4962 • 

LOCAL

  626-937-4270 • 

FAX

 626-937-4279

Page 7 of 8

®

INSTANT-FLOW  MICRO
TROUBLESHOOTING GUIDE

3100-003-001
II-927 06/17 REV 9

Chronomite Laboratories is a Member of Morris Group International™

ELECTRIC TANKLESS WATER HEATER - POINT OF USE

Summary of Contents for M-15L

Page 1: ...com TABLE OF CONTENTS 2 Dimensional Data 3 Installation 4 5 Specifications 6 Troubleshooting 7 Warranty Information 8 Technical Information REQUIRED ITEMS FOR INSTALLATION NOT SUPPLIED Electrical Junc...

Page 2: ...937 4270 FAX 626 937 4279 3100 003 001 II 927 06 17 REV 9 Page 2 of 8 MODEL VOLTAGE ACTIVATION 80 GPM 3 0 LPM 1 0 GPM 3 8 LPM 1 2 GPM 4 5 LPM M 15L 277 0 35 GPM 1 3 LPM 35 F 20 C 28 F 16 C 24 F 13 C M...

Page 3: ...8 INSTANT FLOW MICRO DIMENSIONAL DATA 3100 003 001 II 927 06 17 REV 9 101 8 257 1 1 16 27 17 8 48 1 1 16 27 23 4 70 1 1 16 27 53 4 146 1 4 6 1 4 6 95 8 244 7 32 6 3 5 16 84 2 51 61 4 159 Chronomite L...

Page 4: ...ly open Do not throttle inlet 5 Turn on circuit breaker Turn on water flow to exceed activation point listed in chart 2 The unit is almost ready for use Shut off circuit breaker 6 Check for leaks at a...

Page 5: ...to follow these installation and operation instructions NOTICE Air in the heater may cause the elements to burn out If the water lines are drained allowing air into the heater be sure to follow the fo...

Page 6: ...exceed GPM LPM however less water can always be used Consumer can mix the cold water as with a conventional system See Flow Control Models Chart below CHRONOMITE TECHNICAL SUPPORT TOLL FREE 800 447 4...

Page 7: ...fer to Figure x for location This reading should be between 6 and 30 ohms for each element 8 Check Flow Rate Controlling flow rate is essential to insure proper temperature increase In the case of the...

Page 8: ...local plumbing and or building codes and or regulations 2 Chronomite is not liable under this warranty if the water heater has not been continuously supplied with potable water or the water inlet tem...

Reviews: