UNIT IDENTIFICATION (CONT’D.)

SPARE PARTS LIST FOR ANSI FLANGE HEATERS

Labeling Descriptions

Specific model information such as the unique Chromalox part num-
ber, manufacturing date, third party certifications, etc. can be found by

using the diagram below. For additional information not contained
here, please contact you local Chromalox Sales Office.

9

Flange Size

3"

5"

6"

8"

10"

12"

14"

150# ANSI Flange Gasket

132-017222-015 132-017222-016 132-017222-005 132-017222-007 132-017222-009 132-017222-011 132-017222-013

(1) Set of Flange Bolting & Nuts (rated 150LB*)

168-306161-001 168-306161-002 168-306161-003 168-306161-004 168-306161-005 168-306161-006 168-306161-007

Terminal Housing Cover (E1)

080-013022-001 080-013063-001 080-305809-006 080-305809-008 080-305809-010 080-305809-012 080-305809-014

Blank Service Entrance Plate (E1)

027-014672-001 027-014672-001 080-305942-006 080-305942-008 080-305942-010 080-305942-012 080-305942-014

(1) Set of Cover/Enclosure Bolts & Nuts (E1&E4)

N/A

N/A

168-306161-008 168-306161-008 168-306161-008 168-306161-009 168-306161-009

Terminal Housing Cover (E4)

N/A

N/A

080-305809-006 080-305809-008 080-305809-010 080-305809-012 080-305809-014

Blank Service Entrance Plate (E4)

N/A

N/A

080-305807-006 080-305807-008 080-305807-010 080-305807-012 080-305807-014

Service Entrance Plate Gasket (E4)

N/A

N/A

132-305811-006 132-305811-008 132-305811-010 132-305811-012 132-305811-014

Terminal Housing to Flange Gasket (E4)

N/A

N/A

132-305810-006 132-305810-008 132-305810-010 132-305810-012 132-305810-014

Terminal Housing Cover Gasket (E4)

N/A

N/A

132-305810-006 132-305810-008 132-305810-010 132-305810-012 132-305810-014

Terminal Housing Cover Gasket (E2)

132-305967-004 132-305969-005 132-116937-040 132-116937-044 132-116937-047 132-116937-046 132-116937-050

Terminal Housing Cover (E2)

080-305967-003 080-305969-004 080-306161-021 080-306161-022 080-306161-023 080-306161-024 080-306161-025

(1) Set of Cover/Enclosure Bolts (E2)

N/A

N/A

168-306161-010 168-306161-011 168-306161-012 168-306161-013 168-306161-014

Thermostat Install Kit (Parts to Mount Thermostat-E1)

N/A

N/A

300-306012-009 300-306012-001 300-306012-010 300-306012-012 300-306012-014

Thermostat Install Kit (Parts to Mount Thermostat-E4)

N/A

N/A

300-306012-009 300-306012-001 300-306012-010 300-306012-012 300-306012-014

Thermostat Install Kit (Parts to Mount Thermostat-E2)

N/A

300-306012-005 300-306012-007 300-306012-008 300-306012-011 300-306012-013 300-306012-015

Thermostat (0-100 deg. F)

N/A

300-048518-012 300-048518-012 300-048518-012 300-048518-012 300-048518-012 300-048518-012

Thermostat (60-250 deg. F)

N/A

300-048518-013 300-048518-013 300-048518-013 300-048518-013  300-048518-013  300-048518-013

Thermostat (200-550 deg. F)

N/A

300-048518-014 300-048518-014 300-048518-014 300-048518-014 300-048518-014 300-048518-014

Element Buss Bar 17" (User cut to Length)

N/A

N/A

166-305730-009 166-305730-009 166-305730-009 166-305730-009 166-305730-009

Line Buss Bar 17" (User cut to Length)

N/A

N/A

166-305730-006 166-305730-006 166-305730-006 166-305730-006 166-305730-006

Power Connection Bussing (hardware included)

N/A

N/A

168-306161-015 168-306161-016 168-306161-017 168-306161-018 168-306161-019

Circuit Labels (Pack of 9 unique labels-3 circuits)

168-306161-020

* = Grade SA-325, oiled structural steel.

"TOP" Mark

on flange

Identification

Nameplate

All cautionary

labeling on

cover

Manufacturer's

Nameplate

Additional

third party

labeling

Customer

service

information

label

Summary of Contents for TM Series

Page 1: ...hich depending upon the solution being heated can cause an explosion or fire D Pipe flange sizes in 3 5 6 8 10 12 and 14 inches are standard Other sizes are also available E Units are available with E1 General Purpose E4 Moisture Resistant and E2 Explosion Moisture Resistant terminal enclo sures FIRE HAZARD An integral thermostat if provided is designed for temperature control service only Because...

Page 2: ...ORTANT Heater should never be located at the highest point of the water system Provide expansion tank if necessary A4 Heaters shall be supported if the immersion length is greater than 36 B Vertical Position Figure 4 9 A drip loop is recommended to minimize passage of moisture from condensation along wiring into terminal box enclosure and connections FIRE HAZARD Since heaters are capable of develo...

Page 3: ...rage by at least 25 Be sure to consider the ambient operating temperature and apply the appropriate cor rection factor to the ampacity rating of the wire Heaters with the same voltage and wattage may be connected in series for operation at a higher voltage INSTALLATION cont d THERMOSTATS 10 To prevent moisture accumulation in cryogenic applications or when heater is exposed to freezing temperature...

Page 4: ...R VOLTAGE L2 L1 L3 TM Series 18 Element All sheath materials 12 ELEMENT 2 CIRCUIT 3 PHASE SEE HEATER NAMEPLATE FOR VOLTAGE AL1 AL2 AL3 BL1 BL2 BL3 L1 L2 L3 12 ELEMENT 1 CIRCUIT 3 PHASE SEE HEATER NAMEPLATE FOR VOLTAGE 18 ELEMENT 3 CIRCUIT 3 PHASE SEE HEATER NAMEPLATE FOR VOLTAGE BL1 AL3 AL1 AL2 BL2 BL3 CL2 CL3 CL1 TM Series 45 Element All sheath materials AL1 27 ELEMENT 3 CIRCUIT 3 PHASE SEE HEATE...

Page 5: ...a and for providing Chromalox with hazardous area specifications and requirements for proper equipment design NEC and IEC provide guidelines for evaluating and classifying hazardous locations Safety Devices Approved pressure and or temperature limiting controls must be used on electric heaters and heating elements to ensure safe opera tion in the event of system malfunctions Note Locations includi...

Page 6: ...1 1 2 5 1 CONDUIT OUTLET E1 GENERAL PURPOSE ENCLOSURE FOR UP TO 5 FLANGE E2 EXPLOSION RESISTANT ENCLOSURE FOR UP TO 5 FLANGE E4 MOISTURE RESISTANT ENCLOSURE WITH GASKET UP TO 5 FLANGE 10 1 2 267 Removable Service Entrance Plate Dimple for locating chassis punched conduit opening s E4 MOISTURE RESISTANT ENCLOSURE WITH GASKET 6 AND LARGER FLANGE E1 GENERAL PURPOSE ENCLOSURE FOR 6 AND LARGER FLANGE E...

Page 7: ...ity thermal conductivity of the material and operating temperature are all factors in deter mining the allowable watt density of the element Consult facto ry if in doubt about the proper watt density for the heater in a par ticular application 14 When heating liquids in a large tank the use of several small heaters will provide more uniform heat distribution than a single large heater OPERATION 1 ...

Page 8: ... Heating Elements 45 Forty Five Heating Elements Code Wattage 004P5 4 5 kW use actual kilowatt in 3 digits Code Terminal Housing Style E1 General Pupose E4 Moisture Resistant E2 Explosion Moisture Resistant E5 Explosion Moisture Resistant addition of Group IIC w Acetylene IEC only Code Non Standard Feature Blank Catalog PCN item XX Custom Feature Code Voltage 208 208V 240 240V 380 380V 415 415V 48...

Page 9: ...2 305810 014 Terminal Housing Cover Gasket E2 132 305967 004 132 305969 005 132 116937 040 132 116937 044 132 116937 047 132 116937 046 132 116937 050 Terminal Housing Cover E2 080 305967 003 080 305969 004 080 306161 021 080 306161 022 080 306161 023 080 306161 024 080 306161 025 1 Set of Cover Enclosure Bolts E2 N A N A 168 306161 010 168 306161 011 168 306161 012 168 306161 013 168 306161 014 T...

Page 10: ...50 N RULON WHITE BLVD OGDEN UT 84404 Phone 1 800 368 2493 www chromalox com Limited Warranty Please refer to the Chromalox limited warranty applicable to this product at http www chromalox com customer service policies termsofsale aspx ...

Reviews: