is turned off using RS232 and LAN commands, it can be turned on again
with RS232 and LAN commands.
With the feature disabled, when the display panel enters standby the
display panel is turned off and enters a low power state. To turn the
panel back on, use the Wake on RS232 command with baud rate 38400
or press the power button on the remote control. This is the energy-
saving mode.
Power on Delay
Sets a delay value at power on, from 0 to 2000 ms in steps of 100 ms.
The display panel turns on after the set delay time is expired.
Auto Launch
Configures the auto launch preference as CMS (Start URL), Open
Browser (Open Browser initial page), or Disabled.
Boot Up Picture mode
Configures the picture mode preference at power on. If set as Off, the
last set picture mode is used at power on.
HDMI1 Wake Up
When enabled, if an HDMI input source (HDMI 5V signal) is detected the
display panel wakes up, and when the signal is inactive the display panel
shuts down.
If a schedule is set or an OPS unit is connected to the display panel, this
option is inactive and can not be enabled.
HDMI2 Wake Up
USB
Clone to USB
Copies the database files from the unit to a connected USB device.
Clone from USB
Copies the database files from a connected USB device to the unit.
USB Information
Displays the Current Total space and Free space information of the
connected USB device, and formats the connected USB device.
USB Operations
Highlight and press OK to perform USB operations.
USB Option
Disables the USB ports on the display panel, or select the 5V option to
provide 5 volts power over USB. When set to 5V, browsing the USB
content through the Media Browser is disabled.
OPS Settings
This menu is not available if an OPS is not connected to the display panel.
OPS Information
Displays read-only information about the OPS unit, if supported.
OPS Status
Displays whether the OPS module is on or off. Allows the change of
status via soft PSON signal (0.5s).
Boot Signal
Enables or disables sending a PSON signal when a non-standard OPS
erroneously reports it is ON during bootup.
Power down
Turns the OPS off via hard PSON signal (5s).
Scheduler Settings
Sets the unit to turn on or off automatically at defined time with the
defined input source setting.
If the Source option is set as Last State, the input source will not be
changed at power-up.
If the Source option is set as USB, the media files in the connected USB
device are played back automatically.
Display panel menu contents
Secure Series LCD Panels Installation and Setup Guide–SUHD551-L, SUHD651-L, SUHD751-P, SUHD861-P
26
020-001660-02 Rev. 1 (02-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.