Mounting brackets may block access to the connector ports. To ensure the preferred mount allows
access to the connectors, refer to the display panel line drawings on www.christiedigital.com for
measurements.
When mounting the SUHD751-P and SUHD861-P in portrait mode, ensure the ports and OPS slot are
on the bottom edge of the display panel. It may be necessary to move the Christie name plate to the
bottom edge of the display panel. Use a #1 Phillips screwdriver to remove the screws from the
nameplate, and to remove the extra screws from the secondary nameplate location on the bottom of
the panel.
At the location where the space between tiles is the tightest, use the spacer tool to ensure there is a
minimum of 0.5mm, or the thickness of a credit card, between adjacent LCD display panels.
Related information
Installing the IR extender cable (on page 13)
Installing a display panel on an indented wall
When installing the display panel on an indented wall, ensure there is sufficient space around the
display panel and the wall for ventilation.
The ambient temperature must be between 0-35°C (32-95°F). Do not expose the product to direct
sunlight.
A
Minimum 70 mm
B
Minimum 50 mm
C
Minimum 50 mm
D
Minimum 50 mm
Configuring the display panel after installation
After turning the display panel on for the first time, complete the initial configuration.
1. Power on the display panel.
2. Using the display panel remote, select the display language and press OK.
3. Select the country and press OK