Status
State Value
Description
N/A
No video is being displayed.
51
Frame Locked
N/A
No video is being displayed or an
internal test pattern is being displayed.
Locked
The output is locked to the selected
input(s).
Unlocked
The output is not locked to the selected
input(s).
52
3D Sync
N/A
There is no 3D signal or 3D mode is set
to Off.
Valid 3D Sync
Detects a valid external 3D sync.
Internal 3D Sync
The system is using the internal v-sync
signal because the video is configured as
a Dual-Input. External sync is ignored.
Valid HDMI 3D Sync
Properly detects the built-in HDMI 3D
sync signal.
Invalid 3D Sync (using internal
sync)
Detects an external 3D sync but it is not
locked and/or in phase with the 3D video
signal(s). The system is using the
internal v-sync signal instead but may
have L/R swapped.
No 3D Sync (using internal sync) Cannot detect an external 3D sync. The
system is using the internal v-sync
signal instead but may have L/R
swapped.
53
TSIC Connection
Alias IP: <IP address>
Displays the IP address used to
communicate with the projector through
the SDVoE network.
N/A
Either the card is not present or is not
powered.
Light Group (SST+LGHT?)
The Light Group provides values and fault conditions relating to the light source status for Crimson.
#
Status
State Value
Description
0
Combiner State
On
The combiner is on.
Off
The combiner is off.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System
13
020-102661-04 Rev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.