3-8
CP2000-XB Setup Guide
020-100250-02 Rev. 1 (06-2009)
Section 3: Basic Operation
*
1) A failed interlock automatically prevents power from going to the lamp and disables the lamp button on
the TPC Main menu. Since most interlock alarm conditions are triggered by switches, check the operation of
these switch levers. 2) When you have restored interlock integrity, the lamp button on the TPC Main menu is
automatically re-enabled.
OVER-TEMPERATURE
Card cage is too hot
Power down and cool projector. Ambient temperature may be too high. Check air filter
and fan.
Prism is too hot
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check air filter and sensor. Check liquid cooler fan.
Integrator is too hot
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check air filter and sensor. Check liquid cooler fan.
Red DMD is too hot
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check fluid flow and level. Check air filter. Check liquid cooler fan.
Blue DMD is too hot
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check fluid flow and level. Check air filter. Check liquid cooler fan.
SSM is too hot
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check fluid flow and level. Check air filter.
Ballast is too hot and has shut down
Cool, then cycle the projector down-and-up normally. If the over-temp recurs, there is a
cooling problem in the ballast that may require service. Check ballast fan.
OTHER FANS TOO SLOW
A primary fan is too slow or stopped
Replacement fan may be required.
Card cage fan is too slow or stopped
Replacement fan may be required.
Laminar airflow is too slow or stopped
Replacement LAD filter or fan may be required.
LAMP PROBLEMS
Lamp Life has expired
Replacement of the lamp is recommended.
Unexpected lamp off
Increase Lamp Power. Check that DMDs have not overheated. An interlock may have
momentarily tripped. Lamp may have to be replaced.
Lamp strike failed
If interlocks are OK, make sure the 220V connection near Panel C at the rear of the
projector head (on the underside) is still plugged in. If lamp re-try still fails, replace the
lamp.
OTHER
SSM Communication Error
Check cabling. Cycle projector power for a normal start-up. Check LEDs on card cage
boards, which can indicate a light engine problem instead. Check LVPS/Processor
voltages. Also, if shutter or lamp are functioning normally, SSM likely OK.
I
2
C Communication Error
There may be a power problem with the main electronics (I
2
C). Check LVPS/Proc.
voltage adjustments.
LENS MOUNT
A communications error with the ILS motor con-
trol board has occurred. Please ensure that all
cabling is correctly connected.
Check cabling. Cycle projector power for a normal start-up.
ILS Motor Control Board - Sensor Failure
This error will only be detected on a lens reset or lens calibrate. Check the sensors. It is
cleared by cycling the projector power or performing a lens reset.
ILS Motor Control Board - In Boot/Program Mode
If this message remains for longer than 4 seconds, try re-powering the TPC or upgrading
the MCB software.
ILS Motor Control Board - Main Code CRC
Upgrade MCB software.