6
CHRISTIE DIGITAL SYSTEMS
CineX35 Projector
6-1
May, 2004
6 .
C A L I B R A T I O N , A L I G N M E N T , A N D
A D J U S T M E N T P R O C E D U R E S
The projector has been factory aligned, calibrated, and adjusted prior to shipment. The
following paragraphs contain the necessary information to calibrate, align, and adjust the
various components and assemblies. Always observe standard safety precautions and
maintenance procedures when working on the projector.
6.1. A
N A L O G
R
E A D E R
A
L I G N M E N T A N D
A
D J U S T M E N T S
Refer to Figure 6-1 for these procedures.
1: Clamp Mounting
2: Focus Adjustment
3: Vertical Adjustment
Locking Screw
4: Azimuth Adjustment
Locking Screw
5: Horizontal Adjust.
6: Azimuth Adjustment
7: Horizontal Adjust.
Locking Screw
8: Vertical Adjustment
9: Focus Adjustment
Locking Screw
Figure 6-1: Analog Reader Assembly