3 : O p e r a t i n g t h e P r o j e c t o r
CHRISTIE INC.
CHRISTIE INC. -
-
35/70 Service/PM Manual
July, 1997
H 3 : T h e F A S T F O R W A R D C o m m a n d [ D X , L ]
This diagnostic command moves the film in a forward direction at a rate of 120 fps. The douser is closed.
This command must be followed by a STOP command, or the film will run off the reel.
E
NTRY
:
<CMD-H>, <3>
C
ODE
:
H3
A
CTION
S
:
Move film forward at 120 fps.
S
TATUS
:
Set to
8
.
H 4 : T h e S E T F R A M E C O U N T E R C o m m a n d [ D X ]
This diagnostic command allows the user to load a new value into the frame counter. The command should only be used
if there is a problem with the current value.
E
NTRY
:
<CMD-H>, <4>
C
ODE
:
H4
I
NPUT
:
1. Enter the new value for the frame counter in the counter
format
hh:mm:ss:ff
(see Section 0).
2. Press <ENTER> .
A
CTION
S
:
Set the frame counter.
S
TATUS
:
Unchanged.
H 5 : T h e S E T C U R R E N T S H O W C o m m a n d [ O P ]
This operational command causes a display of the current show and the next show in the two rightmost digits of the
numeric display, respectively. The user may enter a new current show number, if desired. The new value must be a valid
show number. The current show and next show values are displayed for one second before the numeric display reverts to
the frame counter. The new current show value must be entered while the show values are displayed.